CoChat

Noise suppression digital filter for functional magnetic resonance imaging based on image reference data

Buonocore, Michael H., Maddock, Richard J. · 1997 · Magnetic Resonance in Medicine
Cited by 46

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

The central decision in every functional magnetic resonance imaging (fMRI) experiment is whether pixels in brain tissues are showing activation in response to neural stimulus or as a result of noise. Images are degraded not only by random (e.g., thermal) noise, but also by structured noise due to MR system characteristics, cardiac and respiratory pulsations, and patient motion. A novel digital filter has been developed to suppress cardiac and respiratory structured noise in fMRI images, using estimates of structured and random noise power spectra obtained directly from the images. It is an adaptive filter based on stationary noise statistics, and is equivalent in form to a Wiener filter. A mathematical model of the filtering process was developed to understand how the strength and distribution of structured and random noise power influenced filter performance. The filter was tested using images from an auditory activation study in ten subjects. In subjects whose structured noise power was localized to a relatively narrow frequency range, a strong relationship was found, both experimentally (R = 0.975, P < 0.0004 for H o: R = 0) and using the model, between filter performance and the level of structured noise power contaminating the experiment frequency. The filter significantly reduced the rate of false‐positive activations in the subset of subjects whose experiment frequency was relatively heavily contaminated by structured noise. Notch filters, that simply eliminate unwanted frequencies, performed poorly in all subjects. Unlike the proposed Wiener filter, these filters did not suppress structured noise power at the experiment frequency that contributes to false‐positive activations.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.1910380314

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

Metadata

Authors
Buonocore, M. H., & Maddock, R. J.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
1997-09
Volume
38
Issue
3
Pages
456-469
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W2139635499
Cited by
46
References
1
FWCI
5.29
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.