A multiple echo pulse sequence for diffusion tensor imaging and its application in excised rat spinal cords
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
A new imaging sequence for rapid determination of the apparent self‐diffusion tensor of water was developed and tested on fixed excised rat spinal cords. To reduce the time required to determine the tensor, the sequence utilized a new single‐shot approach with multiple spin echoes. An assumption of cylindrical symmetry in the sample was made, thus requiring the measurement of only four of the six unique elements of the tensor. This assumption was found experimentally to be valid, and the results obtained using the new sequence were found to be quantitatively the same as results obtained using a standard spin‐echo sequence.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Diffusion tensor MR imaging of the human brain
Pierpaoli, C., Jezzard, P., Basser, P. J., Barnett, A., & Di Chiro, G. (1996) · Radiology · doi:10.1148/radiology.201.3.8939209 · Cited by 2,664
MR color mapping of myelin fiber orientation
Douek, P., Turner, R., Pekar, J., Patronas, N., & Bihan, D. L. (1991) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199111000-00003 · Cited by 274
Cited by
Diffusion tensor imaging: Concepts and applications
Le Bihan, D., Mangin, J., Poupon, C., Clark, C. A., Pappata, S., Molko, N., & Chabriat, H. (2001) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1076 · Cited by 3,547
“In the case of axial symmetry, only four directions are necessary (tetrahedral encoding) (26), as suggested in the spinal cord (27,28).”
BackgroundLooking into the functional architecture of the brain with diffusion MRI.
Le Bihan, D. (2003) · Nature Reviews Neuroscience · doi:10.1038/nrn1119 · Cited by 1,571
Diffusion MRI at 25: exploring brain tissue structure and function
Le Bihan, D., & Johansen-Berg, H. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2011.11.006 · Cited by 498
The current state-of-the-art of spinal cord imaging: Methods
Stroman, P. W., Wheeler-Kingshott, C., Bacon, M., Schwab, J. M., Bosma, R., Brooks, J., Cadotte, D., Carlstedt, T., Ciccarelli, O., Cohen-Adad, J., et al. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.04.124 · Cited by 334
Structural insights into the rodent CNS via diffusion tensor imaging.
Zhang, J., Aggarwal, M., & Mori, S. (2012) · Trends in Neurosciences · doi:10.1016/j.tins.2012.04.010 · Cited by 73
“Early applications of DTI in the rodent CNS date back more than a decade ago [8,9] and its development since then has been driven primarily by needs arising from neuroscience research (e.”
Background
Metadata
- Authors
- Gulani, V., Iwamoto, G. A., Jiang, H., Shimony, J. S., Webb, A. G., & Lauterbur, P. C.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1997-12
- Volume
- 38
- Issue
- 6
- Pages
- 868-873
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2027408428
- Cited by
- 64
- References
- 2
- FWCI
- 4.91
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.