Localized q‐space imaging of the mouse brain
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Localized q‐space imaging was used to obtain water displacement profiles from mouse brain. These profiles take the form of unidirectional diffusive displacement probability distributions. Two groups of mice were studied, a normal group and a group in which surgery had been performed to produce a unilateral reduction in the supply of blood to the forebrain.q‐Space measurements were made both in vivo and postmortem. The displacement profiles were characterized using the summary parameter prob[d< 10], which is the proportion of water molecules that undergo a net diffusive displacement that is less than ±10 μm, during the diffusion period (50 ms). The range of prob[d< 10] values in the normal group was 0.71 to 0.77 in vivo compared with 0.78 to 0.87 in the impaired hemisphere of the surgically treated group. An increase in prob[d< 10] occurred postmortem to yield values in the range 0.79 to 0.81 and 0.80 to 0.89 in the normal and surgically treated group, respectively. These observations are consistent with the diffusion‐weighted image intensity changes that occur after a period of ischemia.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Moseley, M. E., Cohen, Y., Mintorovitch, J., Chileuitt, L., Shimizu, H., Kucharczyk, J., Wendland, M. F., & Weinstein, P. R. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910140218 · Cited by 1,644
Cited by
The basis of anisotropic water diffusion in the nervous system—A technical review.
Beaulieu, C. (2002) · NMR in Biomedicine · doi:10.1002/nbm.782 · Cited by 4,628
Tuch, D. S. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20279 · Cited by 1,880
Composite hindered and restricted model of diffusion (CHARMED) MR imaging of the human brain
Assaf, Y., & Basser, P. J. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2005.03.042 · Cited by 856
“Among the ‘‘model-free’’ approaches, there is q space imaging (QSI) (Assaf et al., 2000; King et al., 1997), diffusion spectrum imaging (DSI) (Wedeen et al.”
BackgroundMethodInfluentialDiffusion MRI of complex neural architecture.
Tuch, D. S., Reese, T. G., Wiegell, M. R., & Wedeen, V. J. (2003) · Neuron · doi:10.1016/s0896-6273(03)00758-x · Cited by 698
Assaf, Y., Freidlin, R. Z., Rohde, G. K., & Basser, P. J. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20274 · Cited by 519
Metadata
- Authors
- King, M. D., Houseman, J., Gadian, D. G., & Connelly, A.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1997-12
- Volume
- 38
- Issue
- 6
- Pages
- 930-937
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2020204431
- Cited by
- 67
- References
- 1
- FWCI
- 1.89
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.