The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Functional MRI of brain activation induced by scanner acoustic noise
Abstract
A method is introduced by which brain activation caused by the acoustic noise associated with echo planar imaging (EPI) is mapped. Two types of time series were compared. The first time series, considered the “task,” involved applying only EPI gradients for 20 s without the application of RF pulses, then, without pause, starting image collection. The second, considered the “control,” involved typical sequential image acquisition without the prior gradient pulses. Subtraction of the first 5 s of the two time series revealed signal enhancement mainly in the primary auditory cortex. The technique was validated using a motor cortex task that mimicked the hypothesized scanner noise induced activation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Brain magnetic resonance imaging with contrast dependent on blood oxygenation.
Ogawa, S., Lee, T. M., Kay, A. R., & Tank, D. W. (1990) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.87.24.9868 · Cited by 6,483
Dynamic magnetic resonance imaging of human brain activity during primary sensory stimulation.
Kwong, K. K., Belliveau, J. W., Chesler, D. A., Goldberg, I. E., Weisskoff, R. M., Poncelet, B. P., Kennedy, D. N., Hoppel, B. E., Cohen, M. S., & Turner, R. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.12.5675 · Cited by 4,212
Time course EPI of human brain function during task activation
Bandettini, P. A., Wong, E. C., Hinks, R. S., Tikofsky, R. S., & Hyde, J. S. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910250220 · Cited by 1,935
Self-citation
Cited by
?sparse? temporal sampling in auditory fMRI
Hall, D. A., Haggard, M. P., Akeroyd, M. A., Palmer, A. R., Summerfield, A. Q., Elliott, M. R., Gurney, E. M., & Bowtell, R. W. (1999) · Human Brain Mapping · doi:10.1002/(sici)1097-0193(1999)7:3<213::aid-hbm5>3.0.co;2-n · Cited by 869
Activation of Heschl’s Gyrus during Auditory Hallucinations
Dierks, T., Linden, D. E. J., Jandl, M., Formisano, E., Goebel, R., Lanfermann, H., & Singer, W. (1999) · Neuron · doi:10.1016/s0896-6273(00)80715-1 · Cited by 755
Mapping auditory hallucinations in schizophrenia using functional magnetic resonance imaging
Shergill, S. S., Brammer, M. J., Williams, S. C. R., Murray, R. M., & McGuire, P. K. (2000) · Archives of General Psychiatry · doi:10.1001/archpsyc.57.11.1033 · Cited by 666
Study design in fMRI: Basic principles
Amaro, E., & Barker, G. J. (2006) · Brain and Cognition · doi:10.1016/j.bandc.2005.11.009 · Cited by 517
Right parietal cortex is involved in the perception of sound movement in humans
Griffiths, T. D., Rees, G., Rees, A., Green, G. G. R., Witton, C., Rowe, D., Büchel, C., Turner, R., & Frackowiak, R. S. J. (1998) · Nature Neuroscience · doi:10.1038/276 · Cited by 264
Metadata
- Authors
- Bandettini, P. A., Jesmanowicz, A., van Kylen, J., Birn, R. M., & Hyde, J. S.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1998-03
- Volume
- 39
- Issue
- 3
- Pages
- 410-416
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2165965885
- Cited by
- 235
- References
- 3
- FWCI
- 18.18
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Functional MRI of brain activation induced by scanner acoustic noise. https://app.cochat.ai/papers/10.1002/mrm.1910390311
- The paper
- Bandettini, P. A., Jesmanowicz, A., van Kylen, J., Birn, R. M., & Hyde, J. S. (1998). Functional MRI of brain activation induced by scanner acoustic noise. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.1910390311
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.