Volumetric spectroscopic imaging with spiral‐based k‐space trajectories
The DOI matches its Crossref record.
Abstract
Spiral‐based k‐space trajectories were applied in a spectroscopic imaging sequence with time‐varying readout gradients to collect volumetric chemical shift information. In addition to spectroscopic imaging of low signal‐to‐noise ratio (SNR) brain metabolites, the spiral trajectories were used to rapidly collect reference signals from the high SNR water signal to automatically phase the spectra and to aid the reconstruction of metabolite maps. Spectral‐spatial pulses were used for excitation and water suppression. The pulses were designed to achieve stable phase profiles in the presence of up to 20% variation in the radiofrequency field. A gridding algorithm was used to resample the data onto a rectilinear grid before fast Fourier transforms. This method was demonstrated by in vivo imaging of brain metabolites at 1.5 T with 10 slices of 18 × 18 pixels each. Nominal voxel size was 1.1 cc, spectral bandwidth was 400 Hz, scan time was 18 min for the metabolite scan and 3 min for the reference scan.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
In Vivo Magnetic Resonance Spectroscopy in Cancer
Gillies, R. J., & Morse, D. L. (2005) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.7.060804.100411 · Cited by 261
Self‐navigated interleaved spiral (SNAILS): Application to high‐resolution diffusion tensor imaging
Liu, C., Bammer, R., Kim, D., & Moseley, M. E. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20288 · Cited by 247
“Magnetic resonance imaging (MRI) based on spiral readout has been found to be effective in various applications, including functional neuroimaging (10) and spectroscopy (11).”
BackgroundMR spectroscopic imaging: Principles and recent advances
Posse, S., Otazo, R., Dager, S. R., & Alger, J. (2013) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.23945 · Cited by 211
Comprehensive processing, display and analysis for in vivo MR spectroscopic imaging
Maudsley, A. A., Darkazanli, A., Alger, J. R., Hall, L. O., Schuff, N., Studholme, C., Yu, Y., Ebel, A., Frew, A., Goldgof, D., et al. (2006) · NMR in Biomedicine · doi:10.1002/nbm.1025 · Cited by 195
Ebel, A., Dreher, W., & Leibfritz, D. (2006) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2006.06.026 · Cited by 44
Seven-Tesla proton magnetic resonance spectroscopic imaging in adult X-linked adrenoleukodystrophy
Ratai, E., Kok, T., Wiggins, C., Wiggins, G., Grant, E., Gagoski, B., O’Neill, G., Adalsteinsson, E., & Eichler, F. (2008) · Archives of Neurology · doi:10.1001/archneur.65.11.1488 · Cited by 37
“Limitations of our study are the small sample size as well as the limited spatial coverage of regions of interest, which we are addressing with full-brain spiral spectroscopic imaging.(25) The expanded coverage of such methods, combined with segmented high-resolution structural images, will allow us to analyze the tra…”
Metadata
- Authors
- Adalsteinsson, E., Irarrazabal, P., Topp, S., Meyer, C., Macovski, A., & Spielman, D. M.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1998-06
- Volume
- 39
- Issue
- 6
- Pages
- 889-898
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2013737641
- Cited by
- 202
- References
- 0
- FWCI
- 4.36
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.