Quantitative spectroscopic imaging of the human brain
The DOI matches its Crossref record.
Abstract
A method to provide B1 correction and cerebrospinal fluid (CSF) referencing is developed and applied to spectroscopic imaging of the human brain at 4.1 T using a volume head coil. The B1 image allows rapid determination of the spatially dependent B1 that is then used to compensate for the B1 sensitivity of the spectroscopic sequence. The reference signal is acquired from CSF located in a lateral ventricular position using a point‐resolved echo spectroscopy (PRESS) acquisition. The CSF spectrum is also corrected for B1 dependence. Together with T2 and T1 corrections, this method is used to provide quantitative values of N‐acetylaspartate (NAA), creatine (Cr), and choline (Ch). The metabolite concentrations obtained from a spectroscopic imaging slice through the ventricles in seven normal controls are in good agreement with previously published literature values. This method is applied in a patient with secondary progressive multiple sclerosis, showing separate areas of abnormalities in both NAA and Cr.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Yarnykh, V. L. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21120 · Cited by 1,026
In vivo 1 H NMR spectroscopy of the human brain at 7 T
Tkáč, I., Andersen, P., Adriany, G., Merkle, H., Uǧurbil, K., & Gruetter, R. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1213 · Cited by 394
“Increased sensitivity at 4 T has allowed increased spatial resolution in spectroscopic imaging (SI), which resulted in the evaluation of metabolite concentration differences between gray and white matter based on image segmentation (14,15).”
Proton magnetic resonance spectroscopic imaging of human breast cancer: A preliminary study
Jacobs, M. A., Barker, P. B., Bottomley, P. A., Bhujwalla, Z., & Bluemke, D. A. (2004) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.10427 · Cited by 248
Single‐voxel proton MRS of the human brain at 1.5T and 3.0T
Barker, P. B., Hearshen, D. O., & Boska, M. D. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1104 · Cited by 208
Li, B. S. Y., Wang, H., & Gonen, O. (2003) · Magnetic Resonance Imaging · doi:10.1016/s0730-725x(03)00181-4 · Cited by 202
Metadata
- Authors
- Pan, J. W., Twieg, D. B., & Hetherington, H. P.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1998-09
- Volume
- 40
- Issue
- 3
- Pages
- 363-369
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2122591615
- Cited by
- 98
- References
- 0
- FWCI
- 8.36
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Quantitative spectroscopic imaging of the human brain. https://app.cochat.ai/papers/10.1002/mrm.1910400305
- The paper
- Pan, J. W., Twieg, D. B., & Hetherington, H. P. (1998). Quantitative spectroscopic imaging of the human brain. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.1910400305
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.