CoChat

Accurate determination of spin‐density and T1 in the presence of RF‐field inhomogeneities and flip‐angle miscalibration

Venkatesan, Ramesh, Lin, Weili, Haacke, E. Mark · 1998 · Magnetic Resonance in Medicine
Cited by 149

The DOI matches its Crossref record.

Abstract

A method is presented for the accurate extraction of relative spin‐density (ρo) and spin‐lattice relaxation time (T1) in the presence of RF‐field inhomogeneities and flip‐angle miscalibration. The method requires collecting images at several flip‐angles with a three‐dimensional, spoiled steady‐state, gradient‐echo imaging sequence. Results show that the predominant effect of an overestimated flip‐angle is to shift the T1 estimate to a higher value, whereas reductions in the normalized RF‐field from unity cause ρo and T1 distributions to be skewed toward lower values. Phantom and in vivo results demonstrate that the proposed method overcomes both of these systematic errors. The method was shown to be valid for up to a 50% reduction in RF sensitivity. A self‐consistency argument was used to validate the absence of systematic errors in the extracted ρo and T1 values over a large number of voxels. This made it possible to obtain a very precise estimate of muscle T1 at 1.5 T, yielding a 95% confidence interval of (1077.7 ± 3.5) ms.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.1910400412

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 149

Metadata

Authors
Venkatesan, R., Lin, W., & Haacke, E. M.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
1998-10
Volume
40
Issue
4
Pages
592-602
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W1990499131
Cited by
149
References
0
FWCI
1.45
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Accurate determination of spin‐density and T1 in the presence of RF‐field inhomogeneities and flip‐angle miscalibration. https://app.cochat.ai/papers/10.1002/mrm.1910400412
The paper
Venkatesan, R., Lin, W., & Haacke, E. M. (1998). Accurate determination of spin‐density and T1 in the presence of RF‐field inhomogeneities and flip‐angle miscalibration. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.1910400412

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.