Accurate determination of spin‐density and T1 in the presence of RF‐field inhomogeneities and flip‐angle miscalibration
The DOI matches its Crossref record.
Abstract
A method is presented for the accurate extraction of relative spin‐density (ρo) and spin‐lattice relaxation time (T1) in the presence of RF‐field inhomogeneities and flip‐angle miscalibration. The method requires collecting images at several flip‐angles with a three‐dimensional, spoiled steady‐state, gradient‐echo imaging sequence. Results show that the predominant effect of an overestimated flip‐angle is to shift the T1 estimate to a higher value, whereas reductions in the normalized RF‐field from unity cause ρo and T1 distributions to be skewed toward lower values. Phantom and in vivo results demonstrate that the proposed method overcomes both of these systematic errors. The method was shown to be valid for up to a 50% reduction in RF sensitivity. A self‐consistency argument was used to validate the absence of systematic errors in the extracted ρo and T1 values over a large number of voxels. This made it possible to obtain a very precise estimate of muscle T1 at 1.5 T, yielding a 95% confidence interval of (1077.7 ± 3.5) ms.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Yarnykh, V. L. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21120 · Cited by 1,026
McRobbie, D. W., Moore, E. A., Graves, M. J., & Prince, M. R. (2017) · Cambridge University Press eBooks · doi:10.1017/9781107706958 · Cited by 752
Relaxation effects in the quantification of fat using gradient echo imaging
Bydder, M., Yokoo, T., Hamilton, G., Middleton, M. S., Chavez, A. D., Schwimmer, J. B., Lavine, J. E., & Sirlin, C. B. (2008) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2007.08.012 · Cited by 394
Cheng, H. M., & Wright, G. A. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20791 · Cited by 351
Using high-resolution quantitative mapping of R1 as an index of cortical myelination
Lutti, A., Dick, F., Sereno, M. I., & Weiskopf, N. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.06.005 · Cited by 346
“standards for fMRI (Friedman and Glover, 2006) will improve the sensitivity of qMRI in multi-center studies (Levesque et al., 2011; Venkatesan et al., 1998).”
InfluentialQuantitative magnetic resonance imaging of brain anatomy and in vivo histology
Weiskopf, N., Edwards, L. J., Helms, G., Mohammadi, S., & Kirilina, E. (2021) · Nature Reviews Physics · doi:10.1038/s42254-021-00326-1 · Cited by 300
Quantitative FLASH MRI at 3T using a rational approximation of the Ernst equation
Helms, G., Dathe, H., & Dechent, P. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21542 · Cited by 231
Preibisch, C., & Deichmann, R. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21776 · Cited by 230
Vrenken, H., Geurts, J. J. G., Knol, D. L., van Dijk, L. N., Dattola, V., Jasperse, B., van Schijndel, R. A., Polman, C. H., Castelijns, J. A., Barkhof, F., et al. (2006) · Radiology · doi:10.1148/radiol.2403050569 · Cited by 205
Yarnykh, V. L. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22394 · Cited by 170
Optimization and validation of methods for mapping of the radiofrequency transmit field at 3T
Lutti, A., Hutton, C., Finsterbusch, J., Helms, G., & Weiskopf, N. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22421 · Cited by 166
“Repeated measures ANOVA showed a dependence of B1-mean on the B þ 1 mapping method (F 1⁄4 84, df 1⁄4 (3,21), P < 0.”
BackgroundMethodInfluentialHarrison, N. A., Cooper, E., Dowell, N. G., Keramida, G., Voon, V., Critchley, H. D., & Cercignani, M. (2015) · Biological Psychiatry · doi:10.1016/j.biopsych.2014.09.023 · Cited by 129
“A T1 map was calculated for all data sets by fitting the theoretical spoiled gradient echo as a function of the flip angle to the signal measured by the three-dimensional fast low-angle shot sequences (34).”
Quantitative Gd‐DOTA uptake from cerebrospinal fluid into rat brain using 3D VFA‐SPGR at 9.4T
Lee, H., Mortensen, K., Sanggaard, S., Koch, P., Brunner, H., Quistorff, B., Nedergaard, M., & Benveniste, H. (2018) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26779 · Cited by 110
Mancini, M., Giulietti, G., Dowell, N., Spanò, B., Harrison, N., Bozzali, M., & Cercignani, M. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2017.09.018 · Cited by 43
“T1 maps were obtained by fitting the 3 FLASH volumes to theoretical voxel values for the spoiled gradient echo for the three flip angles (Venkatesan et al., 1998).”
Metadata
- Authors
- Venkatesan, R., Lin, W., & Haacke, E. M.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1998-10
- Volume
- 40
- Issue
- 4
- Pages
- 592-602
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W1990499131
- Cited by
- 149
- References
- 0
- FWCI
- 1.45
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.