The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Automated spectral analysis III: Application to in Vivo proton MR Spectroscopy and spectroscopic imaging
Abstract
An automated method for analysis of in vivo proton magnetic resonance (MR) spectra and reconstruction of metabolite distributions from MR spectroscopic imaging (MRSI) data is described. A parametric spectral model using acquisition specific, a priori information is combined with a wavelet‐based, nonparametric characterization of baseline signals. For image reconstruction, the initial fit estimates were additionally modified according to a priori spatial constraints. The automated fitting procedure was applied to four different examples of MRS data obtained at 1.5 T and 4.1 T. For analysis of major metabolites at medium TE values, the method was shown to perform reliably even in the presence of large baseline signals and relatively poor signal‐to‐noise ratios typical of in vivo proton MRSI. identification of additional metabolites was also demonstrated for short TE data. Automated formation of metabolite images will greatly facilitate and expand the clinical applications of MR spectroscopic imaging.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Robust Locally Weighted Regression and Smoothing Scatterplots
Cleveland, W. S. (1979) · Journal of the American Statistical Association · doi:10.1080/01621459.1979.10481038 · Cited by 11,594
Adapting to Unknown Smoothness via Wavelet Shrinkage
Donoho, D. L., & Johnstone, I. M. (1995) · Journal of the American Statistical Association · doi:10.1080/01621459.1995.10476626 · Cited by 4,630
Estimation of metabolite concentrations from localized in vivo proton NMR spectra
Provencher, S. W. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910300604 · Cited by 3,655
Computer Simulations in Magnetic Resonance. An Object-Oriented Programming Approach
Smith, S. A., Levante, T. O., Meier, B. H., & Ernst, R. R. (1994) · Journal of Magnetic Resonance, Series A · doi:10.1006/jmra.1994.1008 · Cited by 710
Michaelis, T., Merboldt, K. D., Bruhn, H., Hänicke, W., & Frahm, J. (1993) · Radiology · doi:10.1148/radiology.187.1.8451417 · Cited by 556
Acute stroke: evaluation with serial proton MR spectroscopic imaging.
Barker, P. B., Gillard, J. H., van Zijl, P. C., Soher, B. J., Hanley, D. F., Agildere, A. M., Oppenheimer, S. M., & Bryan, R. N. (1994) · Radiology · doi:10.1148/radiology.192.3.8058940 · Cited by 174
Self-citationBehar, K. L., & Ogino, T. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910170202 · Cited by 173
On the identification of cerebral metabolites in localized 1H NMR spectra of human brain In vivo
Michaelis, T., Merboldt, K., Hänicke, W., Gyngell, M. L., Bruhn, H., & Frahm, J. (1991) · NMR in Biomedicine · doi:10.1002/nbm.1940040211 · Cited by 168
Ende, G. R., Laxer, K. D., Knowlton, R. C., Matson, G. B., Schuff, N. W., Fein, G., & Weiner, M. W. (1997) · Radiology · doi:10.1148/radiology.202.3.9051038 · Cited by 141
Quality: quantification improvement by converting lineshapes to the lorentzian type
de Graaf, A. A., van Dijk, J. E., & BoéE, W. M. M. J. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910130302 · Cited by 124
Cited by
Proton NMR chemical shifts and coupling constants for brain metabolites
Govindaraju, V., Young, K., & Maudsley, A. A. (2000) · NMR in Biomedicine · doi:10.1002/1099-1492(200005)13:3<129::aid-nbm619>3.0.co;2-v · Cited by 1,689
Self-citationPfeuffer, J., Tkáč, I., Provencher, S. W., & Gruetter, R. (1999) · Journal of Magnetic Resonance · doi:10.1006/jmre.1999.1895 · Cited by 469
Issues of spectral quality in clinical 1H‐magnetic resonance spectroscopy and a gallery of artifacts
Kreis, R. (2004) · NMR in Biomedicine · doi:10.1002/nbm.891 · Cited by 430
1H MR Spectroscopy of the Brain: Absolute Quantification of Metabolites
Jansen, J. F. A., Backes, W. H., Nicolay, K., & Kooi, M. E. (2006) · Radiology · doi:10.1148/radiol.2402050314 · Cited by 405
Time‐domain semi‐parametric estimation based on a metabolite basis set
Ratiney, H., Sdika, M., Coenradie, Y., Cavassila, S., Ormondt, D. V., & Graveron‐Demilly, D. (2005) · NMR in Biomedicine · doi:10.1002/nbm.895 · Cited by 295
Metadata
- Authors
- Soher, B. J., Young, K., Govindaraju, V., & Maudsley, A. A.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1998-12
- Volume
- 40
- Issue
- 6
- Pages
- 822-831
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2166080742
- Cited by
- 260
- References
- 23
- FWCI
- 13.82
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Automated spectral analysis III: Application to in Vivo proton MR Spectroscopy and spectroscopic imaging. https://app.cochat.ai/papers/10.1002/mrm.1910400607
- The paper
- Soher, B. J., Young, K., Govindaraju, V., & Maudsley, A. A. (1998). Automated spectral analysis III: Application to in Vivo proton MR Spectroscopy and spectroscopic imaging. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.1910400607
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.