The DOI matches its Crossref record.
Inversion recovery TrueFISP: Quantification of T1, T2, and spin density
Abstract
A novel procedure is proposed to extract T1, T2, and relative spin density from the signal time course sampled with a series of TrueFISP images after spin inversion. Generally, the recovery of the magnetization during continuous TrueFISP imaging can be described in good approximation by a three parameter monoexponential function S(t) = Sstst(1‐INV exp(‐t/T). This apparent relaxation time T ≤ T1 depends on the flip angle as well as on both T1 and T2. Here, it is shown that the ratio T1/T2 can be directly extracted from the inversion factor INV, which describes the relation of the signal value extrapolated to t = 0 and the steady‐state signal. Analytical expressions are given for the derivation of T1, T2, and relative spin density directly from the fit parameters. Phantom results show excellent agreement with single point reference measurements. In human volunteers T1, T2, and spin density maps in agreement with literature values were obtained. Magn Reson Med 51:661–667, 2004. © 2004 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Magnetic resonance fingerprinting
Ma, D., Gulani, V., Seiberlich, N., Liu, K., Sunshine, J. L., Duerk, J. L., & Griswold, M. A. (2013) · Nature · doi:10.1038/nature11971 · Cited by 1,577
Olson, E. S., Jiang, T., Aguilera, T. A., Nguyen, Q. T., Ellies, L. G., Scadeng, M., & Tsien, R. Y. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0910283107 · Cited by 567
Carlier, P. G., Marty, B., Scheidegger, O., Loureiro de Sousa, P., Baudin, P.-Y., Snezhko, E., & Vlodavets, D. (2016) · Journal of Neuromuscular Diseases · doi:10.3233/jnd-160145 · Cited by 186
European Society of Radiology (ESR) (2015) · Insights into Imaging · doi:10.1007/s13244-015-0403-3 · Cited by 59
Myelin mapping in the living mouse brain using manganese-enhanced magnetization transfer MRI
Watanabe, T., Frahm, J., & Michaelis, T. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2009.09.050 · Cited by 21
Metadata
- Authors
- Schmitt, P., Griswold, M. A., Jakob, P. M., Kotas, M., Gulani, V., Flentje, M., & Haase, A.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2004-03-26
- Volume
- 51
- Issue
- 4
- Pages
- 661-667
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2123935167
- Cited by
- 242
- References
- 0
- FWCI
- 6.95
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Inversion recovery TrueFISP: Quantification of T1, T2, and spin density. https://app.cochat.ai/papers/10.1002/mrm.20058
- The paper
- Schmitt, P., Griswold, M. A., Jakob, P. M., Kotas, M., Gulani, V., Flentje, M., & Haase, A. (2004). Inversion recovery TrueFISP: Quantification of T1, T2, and spin density. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.20058
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.