The DOI matches its Crossref record.
500‐element ultrasound phased array system for noninvasive focal surgery of the brain: A preliminary rabbit study with ex vivo human skulls
Abstract
The aim of this study was to test a prototype MRI‐compatible focused ultrasound phased array system for trans‐skull brain tissue ablation. Rabbit thigh muscle and brain were sonicated with a prototype, hemispherical 500‐element ultrasound phased array operating at frequencies of 700–800 kHz. An ex vivo human skull sample was placed between the array and the animal tissue. The temperature elevation during 20–30‐sec sonications was monitored using MRI thermometry. The induced focal lesions were observed in T2 and contrast‐enhanced T1‐weighted fast spin echo images. Whole brain histology evaluation was performed after the sonications. The results showed that sharp temperature elevations can be produced both in the thigh muscle and in the brain. High‐power sonications (600–1080 W) produced peak temperatures up to 55°C and focal lesions that were consistent with thermal tissue damage. The lesion size was found to increase with increasing peak temperature. The device was then modified to operate in the orientation that will be used in the clinic and successfully tested in phantom experiments. As a conclusion, this study demonstrates that it is possible to create ultrasound‐induced lesions in vivo through a human skull under MRI guidance with this large‐scale phased array. Magn Reson Med 52:100–107, 2004. © 2004 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
McDannold, N., Clement, G. T., Black, P., Jolesz, F., & Hynynen, K. (2010) · Neurosurgery · doi:10.1227/01.neu.0000360379.95800.2f · Cited by 555
Self-citationUltrasonic neuromodulation by brain stimulation with transcranial ultrasound
Tufail, Y., Yoshihiro, A., Pati, S., Li, M. M., & Tyler, W. J. (2011) · Nature Protocols · doi:10.1038/nprot.2011.371 · Cited by 473
Image-Guided Transcranial Focused Ultrasound Stimulates Human Primary Somatosensory Cortex
Lee, W., Kim, H., Jung, Y., Song, I.-U., Chung, Y. A., & Yoo, S.-S. (2015) · Scientific Reports · doi:10.1038/srep08743 · Cited by 414
Current approaches to enhance CNS delivery of drugs across the brain barriers
Lu, C.-T., Zhao, Y.-Z., Wong, H. L., Cai, J., Peng, L., & Tian, X.-Q. (2014) · International Journal of Nanomedicine · doi:10.2147/ijn.s61288 · Cited by 350
McDannold, N., Vykhodtseva, N., Raymond, S., Jolesz, F. A., & Hynynen, K. (2005) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2005.07.010 · Cited by 323
Self-citation
Metadata
- Authors
- Hynynen, K., Clement, G. T., McDannold, N., Vykhodtseva, N., King, R., White, P. J., Vitek, S., & Jolesz, F. A.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2004-06-28
- Volume
- 52
- Issue
- 1
- Pages
- 100-107
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2144352085
- Cited by
- 340
- References
- 0
- FWCI
- 14.64
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: 500‐element ultrasound phased array system for noninvasive focal surgery of the brain: A preliminary rabbit study with ex vivo human skulls. https://app.cochat.ai/papers/10.1002/mrm.20118
- The paper
- Hynynen, K., Clement, G. T., McDannold, N., Vykhodtseva, N., King, R., White, P. J., Vitek, S., & Jolesz, F. A. (2004). 500‐element ultrasound phased array system for noninvasive focal surgery of the brain: A preliminary rabbit study with ex vivo human skulls. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.20118
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.