500‐element ultrasound phased array system for noninvasive focal surgery of the brain: A preliminary rabbit study with ex vivo human skulls

Hynynen, Kullervo, Clement, Gregory T., McDannold, Nathan, Vykhodtseva, Natalia, King, Randy, White, P. Jason, Vitek, Shuki, Jolesz, Ferenc A.·2004·Magnetic Resonance in Medicine

Abstract

The aim of this study was to test a prototype MRI‐compatible focused ultrasound phased array system for trans‐skull brain tissue ablation. Rabbit thigh muscle and brain were sonicated with a prototype, hemispherical 500‐element ultrasound phased array operating at frequencies of 700–800 kHz. An ex vivo human skull sample was placed between the array and the animal tissue. The temperature elevation during 20–30‐sec sonications was monitored using MRI thermometry. The induced focal lesions were observed in T2 and contrast‐enhanced T1‐weighted fast spin echo images. Whole brain histology evaluation was performed after the sonications. The results showed that sharp temperature elevations can be produced both in the thigh muscle and in the brain. High‐power sonications (600–1080 W) produced peak temperatures up to 55°C and focal lesions that were consistent with thermal tissue damage. The lesion size was found to increase with increasing peak temperature. The device was then modified to operate in the orientation that will be used in the clinic and successfully tested in phantom experiments. As a conclusion, this study demonstrates that it is possible to create ultrasound‐induced lesions in vivo through a human skull under MRI guidance with this large‐scale phased array. Magn Reson Med 52:100–107, 2004. © 2004 Wiley‐Liss, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.20118

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 340

Metadata

Authors
Hynynen, K., Clement, G. T., McDannold, N., Vykhodtseva, N., King, R., White, P. J., Vitek, S., & Jolesz, F. A.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
2004-06-28
Volume
52
Issue
1
Pages
100-107
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W2144352085
Cited by
340
References
0
FWCI
14.64
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: 500‐element ultrasound phased array system for noninvasive focal surgery of the brain: A preliminary rabbit study with ex vivo human skulls. https://app.cochat.ai/papers/10.1002/mrm.20118
The paper
Hynynen, K., Clement, G. T., McDannold, N., Vykhodtseva, N., King, R., White, P. J., Vitek, S., & Jolesz, F. A. (2004). 500‐element ultrasound phased array system for noninvasive focal surgery of the brain: A preliminary rabbit study with ex vivo human skulls. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.20118

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.