Variable‐rate selective excitation for rapid MRI sequences
Open accessThe DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
Balanced steady‐state free precession (SSFP) imaging sequences require short repetition times (TRs) to avoid off‐resonance artifacts. The use of slab‐selective excitations is common, as this can improve imaging speed by limiting the field of view (FOV). However, the necessarily short‐duration excitations have poor slab profiles. This results in unusable slices at the slab edge due to significant flip‐angle variations or aliasing in the slab direction. Variable‐rate selective excitation (VERSE) is a technique by which a time‐varying gradient waveform is combined with a modified RF waveform to provide the same excitation profile with different RF power and duration characteristics. With the use of VERSE, it is possible to design short‐duration pulses with dramatically improved slab profiles. These pulses achieve high flip angles with only minor off‐resonance sensitivity, while meeting SAR limits at 1.5 T. The improved slab profiles will enable more rapid 3D imaging of limited volumes, with more consistent image contrast across the excited slab. Magn Reson Med 52:590–597, 2004. © 2004 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
SENSE: Sensitivity encoding for fast MRI
Pruessmann, K. P., Weiger, M., Scheidegger, M. B., & Boesiger, P. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199911)42:5<952::aid-mrm16>3.0.co;2-s · Cited by 6,251
Magnetic Resonance Imaging: Physical Principles and Sequence Design
Brown, R. W., Cheng, Y. N., Haacke, E. M., Thompson, M. R., & Venkatesan, R. (2014) · doi:10.1002/9781118633953 · Cited by 2,688
Simultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arrays
Sodickson, D. K., & Manning, W. J. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910380414 · Cited by 2,142
Pauly, J., Le Roux, P., Nishimura, D., & Macovski, A. (1991) · IEEE Transactions on Medical Imaging · doi:10.1109/42.75611 · Cited by 800 · cited 3×
“Our design method begins with SLR pulse design (18).”
MethodSelf-citationPrinciples and applications of balanced SSFP techniques
Scheffler, K., & Lehnhardt, S. (2003) · European Radiology · doi:10.1007/s00330-003-1957-x · Cited by 714 · cited 1×
“An excellent description of balanced SSFP imaging was given by Scheffler and Lehnhardt (3).”
MethodSimple Correction Method fork-Space Trajectory Deviations in MRI
Duyn, J. H., Yang, Y., Frank, J. A., & van der Veen, J. W. (1998) · Journal of Magnetic Resonance · doi:10.1006/jmre.1998.1396 · Cited by 359
Variable-rate selective excitation
Conolly, S., Nishimura, D., Macovski, A., & Glover, G. (1988) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(88)90131-x · Cited by 321 · cited 3×
“The VERSE (8) technique is used to distort the RF waveform to match a time-varying slab-select gradient waveform.”
BackgroundMethodSelf-citationPhase and intensity anomalies in fourier transform NMR
Freeman, R., & Hill, H. D. W. (1971) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(71)90047-3 · Cited by 306 · cited 1×
“When balanced SSFP is used, frequency variations due to static field or susceptibility that are beyond a certain range result in significant signal loss (4, 5).”
MethodFrequency offset corrected inversion (FOCI) pulses for use in localized spectroscopy
Ordidge, R. J., Wylezinska, M., Hugg, J. W., Butterworth, E., & Franconi, F. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910360410 · Cited by 199
Detection of BOLD changes by means of a frequency‐sensitive trueFISP technique: preliminary results
Scheffler, K., Seifritz, E., Bilecen, D., D.Sc., R. V., Hennig, J., Deimling, M., & Haacke, E. M. (2001) · NMR in Biomedicine · doi:10.1002/nbm.726 · Cited by 112
Functional brain imaging using a blood oxygenation sensitive steady state
Miller, K. L., Hargreaves, B. A., Lee, J., Ress, D. B., deCharms, R. C., & Pauly, J. M. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10602 · Cited by 92
Self-citationSingle‐breathhold 3D‐trueFISP cine cardiac imaging
Jung, B. A., Hennig, J., & Scheffler, K. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10280 · Cited by 92
Yongbi, M. N., Yang, Y., Frank, J. A., & Duyn, J. H. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199912)42:6<1098::aid-mrm14>3.0.co;2-1 · Cited by 62
Rational approaches to the design of NMR selective pulses
Morris, P. G., McIntyre, D. J. O., Rourke, D. E., & Ngo, J. (1989) · NMR in Biomedicine · doi:10.1002/nbm.1940020514 · Cited by 19 · cited 1×
“chose to use SLR pulse design, the reduced-time VERSE technique presented below will work with other RF pulse design techniques, such as simulated annealing (19) or varying phase approaches (20).”
Method
Cited by
Recent advances in parallel imaging for MRI
Hamilton, J., Franson, D., & Seiberlich, N. (2017) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/j.pnmrs.2017.04.002 · Cited by 251
“A uthor M anuscript A uthor M anuscript A uthor M anuscript A uthor M anuscript VERSE Variable-rate selective excitation Prog Nucl Magn Reson Spectrosc.”
MethodA Review of MR Physics: 3T versus 1.5T
Soher, B. J., Dale, B. M., & Merkle, E. M. (2007) · Magnetic Resonance Imaging Clinics of North America · doi:10.1016/j.mric.2007.06.002 · Cited by 235
“tion) pulses, which can reduce energy deposition without decreasing the flip angle or increasing the excitation time [47].”
BackgroundAdvances in resting state fMRI acquisitions for functional connectomics
Raimondo, L., Oliveira, Ĺ. A. F., Heij, J., Priovoulos, N., Kundu, P., Leoni, R. F., & van der Zwaag, W. (2021) · NeuroImage · doi:10.1016/j.neuroimage.2021.118503 · Cited by 180
Rapid Musculoskeletal MRI in 2021: Clinical Application of Advanced Accelerated Techniques
Fritz, J., Guggenberger, R., & Grande, F. D. (2021) · American Journal of Roentgenology · doi:10.2214/ajr.20.22902 · Cited by 121
Metadata
- Authors
- Hargreaves, B. A., Cunningham, C. H., Nishimura, D. G., & Conolly, S. M.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2004-08-23
- Volume
- 52
- Issue
- 3
- Pages
- 590-597
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2078208347
- Cited by
- 189
- References
- 14
- FWCI
- 6.42
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.