The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Determining the longitudinal relaxation time (T1) of blood at 3.0 Tesla
Open accessAbstract
It is important to determine the longitudinal relaxation time of blood for black blood imaging, as well as for quantifying blood flow by arterial spin labeling (ASL). In this study a circulation system was used to measure blood T1 under physiological conditions at the new clinical field strength of 3.0T. It was found that 1/T1 in s−1 was linearly dependent (P < 0.05) on hematocrit (Hct) within a normal range of 0.38–0.46. The relationships were 1/T1 = (0.52 ± 0.15) · Hct + (0.38 ± 0.06) and 1/T1 = (0.83 ± 0.07) · Hct + (0.28 ± 0.03) for arterial (oxygenation = 92% ± 7%) and venous blood (69% ± 8%), respectively, which led to estimated T1 values of 1664 ± 14 ms (arterial) and 1584 ± 5 ms (venous) at a typical human Hct of 0.42. The temperature dependencies of blood T1 were 22.3 ± 0.6 ms/°C and 19.8 ± 0.8 ms/°C for Hct values of 0.42 and 0.38, respectively. When a head coil transmit/receive setup was used, radiation damping caused a slight reduction (19 ms) of the measured T1 values. Magn Reson Med 52:679–682, 2004. © 2004 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Detre, J. A., Leigh, J. S., Williams, D. S., & Koretsky, A. P. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910230106 · Cited by 1,571
Radiation Damping in Magnetic Resonance Experiments
Bloembergen, N., & Pound, R. V. (1954) · Physical Review · doi:10.1103/physrev.95.8 · Cited by 514
Functional magnetic resonance imaging based on changes in vascular space occupancy
Lu, H., Golay, X., Pekar, J. J., & van Zijl, P. C. M. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10519 · Cited by 463
Self-citationNeuroimaging at 1.5 T and 3.0 T: Comparison of oxygenation‐sensitive magnetic resonance imaging
Krüger, G., Kastrup, A., & Glover, G. H. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1081 · Cited by 325
Bernstein, M. A., Huston, J., Lin, C., Gibbs, G. F., & Felmlee, J. P. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1282 · Cited by 206
Magnetic resonance imaging of stationary blood: A review
Brooks, R. A., & Chiro, G. D. (1987) · Medical Physics · doi:10.1118/1.595994 · Cited by 138
Magnetic relaxation in blood and blood clots
Bryant, R. G., Marill, K. A., Blackmore, C. C., & Francis, C. W. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910130112 · Cited by 136
Effects of hematocrit and oxygen saturation level on blood spin‐lattice relaxation
Silvennoinen, M. J., Kettunen, M. I., & Kauppinen, R. A. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10370 · Cited by 136
Proton NMR relaxation times of human blood samples at 1.5 T and implications for functional MRI.
Barth, M., & Moser, E. (1997) · PubMed · Cited by 118
Golay, X., Silvennoinen, M. J., Zhou, J., Clingman, C. S., Kauppinen, R. A., Pekar, J. J., & van Zijl, P. C. M. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1189 · Cited by 118
Self-citationGonen, O., Gruber, S., Li, B. S. Y., Mlynárik, V., & Moser, E. (2001) · PubMed · Cited by 114
NMR relaxation rates and blood oxygenation level
Meyer, M. ‐., Yu, O., Eclancher, B., Grucker, D., & Chambron, J. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910340215 · Cited by 83
Blood oxygenation dependence of t1 and t2 in the isolated, perfused rabbit heart at 4.7t
Atalay, M. K., Reeder, S. B., Zerhouni, E. A., & Forder, J. R. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910340420 · Cited by 58
FAIR excluding radiation damping (FAIRER)
Zhou, J., Mori, S., & van Zijl, P. C. M. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910400511 · Cited by 42
Wansapura (1999) · doi:10.1002/(sici)1522-2586(199904)9:4
Cited by
Alsop, D. C., Detre, J. A., Golay, X., Günther, M., Hendrikse, J., Hernandez‐Garcia, L., Lu, H., MacIntosh, B. J., Parkes, L. M., Smits, M., et al. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25197 · Cited by 2,206
Self-citationArterial Spin Labeling Perfusion of the Brain: Emerging Clinical Applications
Haller, S., Zaharchuk, G., Thomas, D. L., Lovblad, K.-O., Barkhof, F., & Golay, X. (2016) · Radiology · doi:10.1148/radiol.2016150789 · Cited by 514
Self-citationVariational Bayesian Inference for a Nonlinear Forward Model
Chappell, M. A., Groves, A. R., Whitcher, B., & Woolrich, M. W. (2009) · IEEE Transactions on Signal Processing · doi:10.1109/tsp.2008.2005752 · Cited by 479
Wu, W., Fernández‐Seara, M., Detre, J. A., Wehrli, F. W., & Wang, J. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21403 · Cited by 465
Alterations in Cerebral Metabolic Rate and Blood Supply across the Adult Lifespan
Lu, H., Xu, F., Rodrigue, K. M., Kennedy, K. M., Cheng, Y., Flicker, B., Hebrank, A. C., Uh, J., & Park, D. C. (2011) · Cerebral Cortex · doi:10.1093/cercor/bhq224 · Cited by 399
Self-citation
Metadata
- Authors
- Lu, H., Clingman, C., Golay, X., & van Zijl, P. C. M.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2004-08-23
- Volume
- 52
- Issue
- 3
- Pages
- 679-682
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2040032797
- Cited by
- 685
- References
- 15
- FWCI
- 13.63
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.