The DOI matches its Crossref record.
Perfusion imaging
Abstract
Measurement of tissue perfusion is important for the functional assessment of organs in vivo. Here we report the use of 1 H NMR imaging to generate perfusion maps in the rat brain at 4.7 T. Blood water flowing to the brain is saturated in the neck region with a sliceselective saturation imaging sequence, creating an endogenous tracer in the form of proximally saturated spins. Because proton T 1 times are relatively long, particularly at high field strengths, saturated spins exchange with bulk water in the brain and a steady state is created where the regional concentration of saturated spins is determined by the regional blood flow and regional T 1. Distal saturation applied equidistantly outside the brain serves as a control for effects of the saturation pulses. Average cerebral blood flow in normocapnic rat brain under halothane anesthesia was determined to be 105 ± 16 cc. 100 g−1. min−1 (mean ± SEM, n = 3), in good agreement with values reported in the literature, and was sensitive to increases in arterial p CO 2. This technique allows regional perfusion maps to be measured noninvasively, with the resolution of 1 H MRI, and should be readily applicable to human studies. © 1992 Academic Press, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Dynamic magnetic resonance imaging of human brain activity during primary sensory stimulation.
Kwong, K. K., Belliveau, J. W., Chesler, D. A., Goldberg, I. E., Weisskoff, R. M., Poncelet, B. P., Kennedy, D. N., Hoppel, B. E., Cohen, M. S., & Turner, R. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.12.5675 · Cited by 4,212
Neurocognitive consequences of sleep deprivation
Goel, N., Rao, H., Durmer, J., & Dinges, D. (2009) · Seminars in Neurology · doi:10.1055/s-0029-1237117 · Cited by 2,154
Overview of Functional Magnetic Resonance Imaging
Glover, G. H. (2011) · Neurosurgery Clinics of North America · doi:10.1016/j.nec.2010.11.001 · Cited by 1,024
Toussaint, J.-F., LaMuraglia, G. M., Southern, J. F., Fuster, V., & Kantor, H. L. (1996) · Circulation · doi:10.1161/01.cir.94.5.932 · Cited by 668
Biophysical and Physiological Origins of Blood Oxygenation Level-Dependent fMRI Signals
Kim, S.-G., & Ogawa, S. (2012) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.2012.23 · Cited by 547
Metadata
- Authors
- Detre, J. A., Leigh, J. S., Williams, D. S., & Koretsky, A. P.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1992-01
- Volume
- 23
- Issue
- 1
- Pages
- 37-45
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W4233867216
- Cited by
- 1,571
- References
- 0
- FWCI
- 19.64
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Perfusion imaging. https://app.cochat.ai/papers/10.1002/mrm.1910230106
- The paper
- Detre, J. A., Leigh, J. S., Williams, D. S., & Koretsky, A. P. (1992). Perfusion imaging. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.1910230106
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.