The DOI matches its Crossref record.
A rigorous framework for diffusion tensor calculus
Open accessAbstract
In biological tissue, all eigenvalues of the diffusion tensor are assumed to be positive. Calculations in diffusion tensor MRI generally do not take into account this positive definiteness property of the tensor. Here, the space of positive definite tensors is used to construct a framework for diffusion tensor analysis. The method defines a distance function between a pair of tensors and the associated shortest path (geodesic) joining them. From this distance a method for computing tensor means, a new measure of anisotropy, and a method for tensor interpolation are derived. The method is illustrated using simulated and in vivo data. Magn Reson Med 53:221–225, 2005. © 2004 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Log-Euclidean metrics for fast and simple calculus on diffusion tensors
Arsigny, V., Fillard, P., Pennec, X., & Ayache, N. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20965 · Cited by 1,113
Diffusion tensor imaging and beyond
Tournier, J., Mori, S., & Leemans, A. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22924 · Cited by 921
Intrinsic Statistics on Riemannian Manifolds: Basic Tools for Geometric Measurements
Pennec, X. (2006) · Journal of Mathematical Imaging and Vision · doi:10.1007/s10851-006-6228-4 · Cited by 751
A Differential Geometric Approach to the Geometric Mean of Symmetric Positive-Definite Matrices
Moakher, M. (2005) · SIAM Journal on Matrix Analysis and Applications · doi:10.1137/s0895479803436937 · Cited by 702
Self-citationDiffusion MRI fiber tractography of the brain
Jeurissen, B., Descoteaux, M., Mori, S., & Leemans, A. (2019) · NMR in Biomedicine · doi:10.1002/nbm.3785 · Cited by 574
Frontal circuitry degradation marks healthy adult aging: Evidence from diffusion tensor imaging
Pfefferbaum, A., Adalsteinsson, E., & Sullivan, E. V. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2005.02.034 · Cited by 355
Riemannian geometry for the statistical analysis of diffusion tensor data
Fletcher, P. T., & Joshi, S. (2007) · Signal Processing · doi:10.1016/j.sigpro.2005.12.018 · Cited by 322
Ryan, N. S., Keihaninejad, S., Shakespeare, T. J., Lehmann, M., Crutch, S. J., Malone, I. B., Thornton, J. S., Mancini, L., Hyare, H., Yousry, T., et al. (2013) · Brain · doi:10.1093/brain/awt065 · Cited by 205
Fiber tract-oriented statistics for quantitative diffusion tensor MRI analysis
COROUGE, I., FLETCHER, P., JOSHI, S., GOUTTARD, S., & GERIG, G. (2006) · Medical Image Analysis · doi:10.1016/j.media.2006.07.003 · Cited by 177
Metadata
- Authors
- Batchelor, P. G., Moakher, M., Atkinson, D., Calamante, F., & Connelly, A.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2004-12-22
- Volume
- 53
- Issue
- 1
- Pages
- 221-225
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2008025478
- Cited by
- 190
- References
- 0
- FWCI
- 11.50
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.