The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Gradient echo acquisition for superparamagnetic particles with positive contrast (GRASP): Sequence characterization in membrane and glass superparamagnetic iron oxide phantoms at 1.5T and 3T
Abstract
Iron oxides are used for cell trafficking and identification of macrophages in plaque using MRI. Due to the negative contrast, differentiation between signal loss caused by iron and native low signal in tissue may be problematic. It is, therefore, preferable to achieve positive contrast. The purpose of this study was to test the efficacy of a new MRI sequence GRASP (GRe Acquisition for Superparamagnetic Particles) to generate a positive signal in phantoms containing iron. Membrane phantoms were constructed containing Ferumoxide at 7 concentrations. Standard GRE sequences were modified with user controlled z‐gradient rephasing (±100%). CNR values were determined as a function of echo time (TE) and % rephasing at 1.5T and 3T. T 2* values were determined using multiple double‐echo GRE. The GRASP sequence generated positive signal enhancement in phantoms containing iron. For all rephasing values ≤30%, positive contrast was observed. The CNR generated at 1.5T was greater than the values at 3T for all concentrations tested. Correlation between CNR at 0% and 100% rephasing was observed at 1.5T(R = 0.84). Additionally, correlation between field change across the volume and CNR was observed. In conclusion, GRASP sequences may be used to generate positive signal enhancement in the presence of iron using MRI. Magn Reson Med, 2006. © 2005 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Wang, Y.-X. J., Hussain, S. M., & Krestin, G. P. (2001) · European Radiology · doi:10.1007/s003300100908 · Cited by 1,381
Kooi, M. E., Cappendijk, V. C., Cleutjens, K. B. J. M., Kessels, A. G. H., Kitslaar, P. J. E. H. M., Borgers, M., Frederik, P. M., Daemen, M. J. A. P., & van Engelshoven, J. M. A. (2003) · Circulation · doi:10.1161/01.cir.0000068315.98705.cc · Cited by 798
Cited by
Liu, T., Spincemaille, P., de Rochefort, L., Kressler, B., & Wang, Y. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21828 · Cited by 454
Magnetite nanoparticles for medical MR imaging
Stephen, Z. R., Kievit, F. M., & Zhang, M. (2011) · Materials Today · doi:10.1016/s1369-7021(11)70163-8 · Cited by 432
The ATHEROMA (Atorvastatin Therapy: Effects on Reduction of Macrophage Activity) Study
Tang, T. Y., Howarth, S. P. S., Miller, S. R., Graves, M. J., Patterson, A. J., U-King-Im, J.-M., Li, Z. Y., Walsh, S. R., Brown, A. P., Kirkpatrick, P. J., et al. (2009) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.03.018 · Cited by 389
Terrovitis, J., Stuber, M., Youssef, A., Preece, S., Leppo, M., Kizana, E., Schär, M., Gerstenblith, G., Weiss, R. G., Marbán, E., et al. (2008) · Circulation · doi:10.1161/circulationaha.107.732073 · Cited by 268
Briley-Saebo, K. C., Cho, Y. S., Shaw, P. X., Ryu, S. K., Mani, V., Dickson, S., Izadmehr, E., Green, S., Fayad, Z. A., & Tsimikas, S. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2010.09.023 · Cited by 128
Self-citation
Metadata
- Authors
- Mani, V., Briley‐Saebo, K. C., Itskovich, V. V., Samber, D. D., & Fayad, Z. A.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2005-12-08
- Volume
- 55
- Issue
- 1
- Pages
- 126-135
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2045829393
- Cited by
- 191
- References
- 2
- FWCI
- 14.05
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.