The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Automatic selection of arterial input function using cluster analysis
Open accessAbstract
Quantification of cerebral blood flow (CBF) using dynamic susceptibility contrast MRI requires determination of the arterial input function (AIF) representing the delivery of intravascular tracer to tissue. This is typically accomplished manually by inspection of concentration time curves (CTCs) in regions containing the ICA, VA, and MCA. This is, however, a time consuming and operator dependent procedure. We suggest a completely automatic procedure for establishing the AIF based on a cluster analysis algorithm. In 20 normal subjects CBF maps calculated in 2 slices by the automatic procedure were compared to maps obtained with AIFs selected individually by 7 experienced operators. The average manual to automatic CBF ratio was 1.03 ± 0.15 in the lower slice and 1.05 ± 0.12 in the upper slice, demonstrating excellent agreement between the manual and automatic method. The algorithm provides means for objectively assessing AIF candidates in local AIF search algorithms designed to reduce bias due to delay and dispersion. Given the reproducibility and speed (10 s) of the automatic method, we speculate that it will greatly improve the accuracy of perfusion images and facilitate their use in clinical diagnosis and decision‐making, particularly in acute stroke but also in cerebrovascular disease in general. Magn Reson Med, 2006. © 2006 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Measuring agreement in method comparison studies
Bland, J. M., & Altman, D. G. (1999) · Statistical Methods in Medical Research · doi:10.1177/096228029900800204 · Cited by 9,619
Measuring agreement in method comparison studies
Bland, J. M., & Altman, D. G. (1999) · Statistical Methods in Medical Research · doi:10.1191/096228099673819272 · Cited by 9,619
Cited by
Kickingereder, P., Burth, S., Wick, A., Götz, M., Eidel, O., Schlemmer, H.-P., Maier-Hein, K. H., Wick, W., Bendszus, M., Radbruch, A., et al. (2016) · Radiology · doi:10.1148/radiol.2016160845 · Cited by 446
Cerebral Blood Flow Is the Optimal CT Perfusion Parameter for Assessing Infarct Core
Campbell, B. C. V., Christensen, S., Levi, C. R., Desmond, P. M., Donnan, G. A., Davis, S. M., & Parsons, M. W. (2011) · Stroke · doi:10.1161/strokeaha.111.618355 · Cited by 427
Self-citationReal‐time diffusion‐perfusion mismatch analysis in acute stroke
Straka, M., Albers, G. W., & Bammer, R. (2010) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.22338 · Cited by 401
Kickingereder, P., Sahm, F., Radbruch, A., Wick, W., Heiland, S., Deimling, A. V., Bendszus, M., & Wiestler, B. (2015) · Scientific Reports · doi:10.1038/srep16238 · Cited by 316
Perfusion and vascular permeability: Basic concepts and measurement in DCE-CT and DCE-MRI
Cuenod, C. A., & Balvay, D. (2013) · Diagnostic and Interventional Imaging · doi:10.1016/j.diii.2013.10.010 · Cited by 312
Metadata
- Authors
- Mouridsen, K., Christensen, S., Gyldensted, L., & Østergaard, L.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2006-02
- Volume
- 55
- Issue
- 3
- Pages
- 524-531
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W1995046979
- Cited by
- 214
- References
- 3
- FWCI
- 4.03
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Automatic selection of arterial input function using cluster analysis. https://app.cochat.ai/papers/10.1002/mrm.20759
- The paper
- Mouridsen, K., Christensen, S., Gyldensted, L., & Østergaard, L. (2006). Automatic selection of arterial input function using cluster analysis. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.20759
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.