The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Three‐dimensional radial ultrashort echo‐time imaging with T2 adapted sampling
Abstract
The application of 3D radial sampling of the free‐induction decay to proton ultrashort echo‐time (UTE) imaging is reported. The effects of T2 decay during signal acquisition on the 3D radial point‐spread function are analyzed and compared to 2D radial and 1D sampling. It is found that in addition to the use of ultrashort TE, the proper choice of the acquisition‐window duration TAQ is essential for imaging short‐T2 components. For 3D radial sampling, a maximal signal‐to‐noise ratio (SNR) with negligible decay‐induced loss in spatial resolution is obtained for an acquisition‐window duration of TAQ ≈ 0.69 T2. For 2D and 1D sampling, corresponding values are derived as well. Phantom measurements confirm the theoretical findings and demonstrate the impact of different acquisition‐window durations on SNR and spatial resolution for a given T2 component. In vivo scans show the potential of 3D UTE imaging with T2‐adapted sampling for musculoskeletal imaging using standard MR equipment. The visualization of complex anatomy is demonstrated by extracting curved slices from the isotropically resolved 3D UTE image data. Magn Reson Med, 2006. © 2006 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Fourier Transform and Its Applications
Bracewell, R., & Kahn, P. B. (1966) · American Journal of Physics · doi:10.1119/1.1973431 · Cited by 5,737
Roemer, P. B., Edelstein, W. A., Hayes, C. E., Souza, S. P., & Mueller, O. M. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910160203 · Cited by 2,322
Advances in sensitivity encoding with arbitrary k‐space trajectories
Pruessmann, K. P., Weiger, M., Börnert, P., & Boesiger, P. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1241 · Cited by 1,211
Self-citationThe Fourier transform and its applications
Hautus, M. L. J. (1980) · European Journal of Operational Research · doi:10.1016/0377-2217(80)90120-4 · Cited by 1,144
Magnetic Resonance: An Introduction to Ultrashort TE (UTE) Imaging
Robson, M. D., Gatehouse, P. D., Bydder, M., & Bydder, G. M. (2003) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-200311000-00001 · Cited by 717
A Fast Sinc Function Gridding Algorithm for Fourier Inversion in Computer Tomography
O'Sullivan, J. D. (1985) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.1985.4307723 · Cited by 482
Magnetic Resonance Imaging of Short T2 Components in Tissue
Gatehouse, P. D., & Bydder, G. M. (2003) · Clinical Radiology · doi:10.1053/crad.2003.1157 · Cited by 317
Deblurring for non‐2D fourier transform magnetic resonance imaging
Noll, D. C., Pauly, J. M., Meyer, C. H., Nishimura, D. G., & Macovskj, A. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910250210 · Cited by 222
A strategy for sampling on a sphere applied to 3D selective RF pulse design
Wong, S. T. S., & Roos, M. S. (1994) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910320614 · Cited by 147
Reduced circular field‐of‐view imaging
Scheffler, K., & Hennig, J. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910400319 · Cited by 139
Boron‐11 imaging with a three‐dimensional reconstruction method
Glover, G. H., Pauly, J. M., & Bradshaw, K. M. (1992) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880020109 · Cited by 131
Wu, Y., Ackerman, J. L., Chesler, D. A., Graham, L., Wang, Y., & Glimcher, M. J. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10512 · Cited by 129
Effects of polar sampling in k‐space
Lauzon, M. L., & Rutt, B. K. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910360617 · Cited by 105
Characterization of atherosclerosis with a 1.5‐T imaging system
Gold, G. E., Pauly, J. M., Glover, G. H., et al. (1993) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880030216 · Cited by 91
Cited by
Resting-state fMRI in the human connectome project
Smith, S. M., Beckmann, C. F., Andersson, J., Auerbach, E. J., Bijsterbosch, J., Douaud, G., Duff, E., Feinberg, D. A., Griffanti, L., Harms, M. P., et al. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.05.039 · Cited by 1,502
Advances in diffusion MRI acquisition and processing in the Human Connectome Project
Sotiropoulos, S. N., Jbabdi, S., Xu, J., Andersson, J. L., Moeller, S., Auerbach, E. J., Glasser, M. F., Hernandez, M., Sapiro, G., Jenkinson, M., et al. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.05.057 · Cited by 891
Berker, Y., Franke, J., Salomon, A., Palmowski, M., Donker, H. C. W., Temur, Y., Mottaghy, F. M., Kuhl, C., Izquierdo-Garcia, D., Fayad, Z. A., et al. (2012) · Journal of Nuclear Medicine · doi:10.2967/jnumed.111.092577 · Cited by 344
UTE imaging in the musculoskeletal system
Chang, E. Y., Du, J., & Chung, C. B. (2015) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.24713 · Cited by 276
Metadata
- Authors
- Rahmer, J., Börnert, P., Groen, J., & Bos, C.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2006-03-14
- Volume
- 55
- Issue
- 5
- Pages
- 1075-1082
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2066397523
- Cited by
- 273
- References
- 14
- FWCI
- 7.05
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.