Chemodosimetry of in vivo tumor liposomal drug concentration using MRI
The DOI matches its Crossref record.
Abstract
Effective cancer chemotherapy depends on the delivery of therapeutic drugs to cancer cells at cytotoxic concentrations. However, physiologic barriers, such as variable vessel permeability, high interstitial fluid pressure, and heterogeneous perfusion, make it difficult to achieve that goal. Efforts to improve drug delivery have been limited by the lack of noninvasive tools to evaluate intratumoral drug concentration and distribution. Here we demonstrate that tumor drug concentration can be measured in vivo using T1‐weighted MRI, following systemic administration of liposomes containing both drug (doxorubicin (DOX)) and contrast agent (manganese (Mn)). Mn and DOX concentrations were calculated using T1 relaxation times and Mn:DOX loading ratios, as previously described. Two independent validations by high‐performance liquid chromatography (HPLC) and histologic fluorescence in a rat fibrosarcoma (FSA) model indicate a concordant linear relationship between DOX concentrations determined using T1 and those measured invasively. This method of imaging exhibits potential for real‐time evaluation of chemotherapeutic protocols and prediction of tumor response on an individual patient basis. Magn Reson Med, 2006. © 2006 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Rethinking cancer nanotheranostics
Chen, H., Zhang, W., Zhu, G., Xie, J., & Chen, X. (2017) · Nature Reviews Materials · doi:10.1038/natrevmats.2017.24 · Cited by 1,102
Lammers, T., Aime, S., Hennink, W. E., Storm, G., & Kiessling, F. (2011) · Accounts of Chemical Research · doi:10.1021/ar200019c · Cited by 870
Advances in Magnetic Nanoparticles for Biomedical Applications
Cardoso, V. F., Francesko, A., Ribeiro, C., Bañobre‐López, M., Martins, P., & Lanceros‐Mendez, S. (2018) · Advanced Healthcare Materials · doi:10.1002/adhm.201700845 · Cited by 723
Moradi Kashkooli, F., Soltani, M., & Souri, M. (2020) · Journal of Controlled Release · doi:10.1016/j.jconrel.2020.08.012 · Cited by 514
Kievit, F. M., & Zhang, M. (2011) · Advanced Materials · doi:10.1002/adma.201102313 · Cited by 496
Metadata
- Authors
- Viglianti, B. L., Ponce, A. M., Michelich, C. R., Yu, D., Abraham, S. A., Sanders, L., Yarmolenko, P. S., Schroeder, T., MacFall, J. R., Barboriak, D. P., Colvin, O. M., Bally, M. B., & Dewhirst, M. W.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2006-10-06
- Volume
- 56
- Issue
- 5
- Pages
- 1011-1018
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2169592168
- Cited by
- 129
- References
- 0
- FWCI
- 3.84
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Chemodosimetry of in vivo tumor liposomal drug concentration using MRI. https://app.cochat.ai/papers/10.1002/mrm.21032
- The paper
- Viglianti, B. L., Ponce, A. M., Michelich, C. R., Yu, D., Abraham, S. A., Sanders, L., Yarmolenko, P. S., Schroeder, T., MacFall, J. R., Barboriak, D. P., Colvin, O. M., Bally, M. B., & Dewhirst, M. W. (2006). Chemodosimetry of in vivo tumor liposomal drug concentration using MRI. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.21032
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.