CoChat

Is the “biexponential diffusion” biexponential?

Open access
Kiselev, Valerij G., Il'yasov, Kamil A. · 2007 · Magnetic Resonance in Medicine
Cited by 128

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Diffusion‐weighted signal from the brain,S, deviates from monoexponential dependence on the b‐factor. This property is often referred to as biexponential diffusion, since the corresponding model fits data well. The aim of this study is to examine the necessity of using the biexponential model in homogeneous voxels under isotropic diffusion weighting up to b= 2.5 ms/μm 2. The model is compared to the cumulant expansion of ln S in a power series in b, which takes its origin in fundamental properties of the diffusion‐weighted signal, but diverges at large b. The absence of statistically significant evidences for the biexponential diffusion is demonstrated in gray matter. The cumulant expansion terminated after the term b2 describes data equally well with fewer adjustable parameters. The biexponential model is preferable in voxels with a partial volume of CSF. Magn Reson Med 57:464–469, 2007. © 2007 Wiley‐Liss, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.21164

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 128

Metadata

Authors
Kiselev, V. G., & Il'yasov, K. A.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
2007-02-26
Volume
57
Issue
3
Pages
464-469
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W2080935328
Cited by
128
References
2
FWCI
7.52
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.