The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Array compression for MRI with large coil arrays
Open accessAbstract
Arrays with large numbers of independent coil elements are becoming increasingly available as they provide increased signal‐to‐noise ratios (SNRs) and improved parallel imaging performance. Processing of data from a large set of independent receive channels is, however, associated with an increased memory and computational load in reconstruction. This work addresses this problem by introducing coil array compression. The method allows one to reduce the number of datasets from independent channels by combining all or partial sets in the time domain prior to image reconstruction. It is demonstrated that array compression can be very effective depending on the size of the region of interest (ROI). Based on 2D in vivo data obtained with a 32‐element phased‐array coil in the heart, it is shown that the number of channels can be compressed to as few as four with only 0.3% SNR loss in an ROI encompassing the heart. With twofold parallel imaging, only a 2% loss in SNR occurred using the same compression factor. Magn Reson Med 57:1131–1139, 2007. © 2007 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
SENSE: Sensitivity encoding for fast MRI
Pruessmann, K. P., Weiger, M., Scheidegger, M. B., & Boesiger, P. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199911)42:5<952::aid-mrm16>3.0.co;2-s · Cited by 6,251
Self-citationGeneralized autocalibrating partially parallel acquisitions (GRAPPA)
Griswold, M. A., Jakob, P. M., Heidemann, R. M., Nittka, M., Jellus, V., Wang, J., Kiefer, B., & Haase, A. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10171 · Cited by 5,303
Roemer, P. B., Edelstein, W. A., Hayes, C. E., Souza, S. P., & Mueller, O. M. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910160203 · Cited by 2,322
Simultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arrays
Sodickson, D. K., & Manning, W. J. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910380414 · Cited by 2,142
Electrodynamics and ultimate SNR in parallel MR imaging
Wiesinger, F., Boesiger, P., & Pruessmann, K. P. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20183 · Cited by 282
Self-citationUltimate intrinsic signal‐to‐noise ratio for parallel MRI: Electromagnetic field considerations
Ohliger, M. A., Grant, A. K., & Sodickson, D. K. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10597 · Cited by 238
Specific coil design for SENSE: A six-element cardiac array
Weiger, M., Pruessmann, K. P., Leussler, C. G., R�schmann, P., & Boesiger, P. (2001) · Magnetic Resonance in Medicine · Cited by 183
Self-citationAn introduction to coil array design for parallel MRI
Ohliger, M. A., & Sodickson, D. K. (2006) · NMR in Biomedicine · doi:10.1002/nbm.1046 · Cited by 143
64‐channel array coil for single echo acquisition magnetic resonance imaging
McDougall, M. P., & Wright, S. M. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20568 · Cited by 111
A 16‐element phased‐array head coil
Porter, J. R., Wright, S. M., & Reykowski, A. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910400213 · Cited by 74
Cited by
Feng, L., Grimm, R., Block, K. T., Chandarana, H., Kim, S., Xu, J., Axel, L., Sodickson, D. K., & Otazo, R. (2014) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24980 · Cited by 718
Pushing the limits of in vivo diffusion MRI for the Human Connectome Project
Setsompop, K., Kimmlingen, R., Eberlein, E., Witzel, T., Cohen-Adad, J., McNab, J. A., Keil, B., Tisdall, M. D., Hoecht, P., Dietz, P., et al. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.05.078 · Cited by 545
Real‐time MRI at a resolution of 20 ms
Uecker, M., Zhang, S., Voit, D., Karaus, A., Merboldt, K., & Frahm, J. (2010) · NMR in Biomedicine · doi:10.1002/nbm.1585 · Cited by 434
Knoll, F., Hammernik, K., Zhang, C., Moeller, S., Pock, T., Sodickson, D. K., & Akcakaya, M. (2020) · IEEE Signal Processing Magazine · doi:10.1109/msp.2019.2950640 · Cited by 403
Gadgetron: An open source framework for medical image reconstruction
Hansen, M. S., & Sørensen, T. S. (2013) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24389 · Cited by 339
Metadata
- Authors
- Buehrer, M., Pruessmann, K. P., Boesiger, P., & Kozerke, S.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2007-05-29
- Volume
- 57
- Issue
- 6
- Pages
- 1131-1139
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2009238259
- Cited by
- 257
- References
- 10
- FWCI
- 3.88
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.