CoChat

T1 relaxation in in vivo mouse brain at ultra‐high field

Open access
van de Ven, Rob C.G., Hogers, Bianca, van den Maagdenberg, Arn M.J.M., de Groot, Huub J.M., Ferrari, Michel D., Frants, Rune R., Poelmann, Robert E., van der Weerd, Louise, Kiihne, Suzanne R. · 2007 · Magnetic Resonance in Medicine
Cited by 36

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Accurate knowledge of relaxation times is imperative for adjustment of MRI parameters to obtain optimal signal‐to‐noise ratio (SNR) and contrast. As small animal MRI studies are extended to increasingly higher magnetic fields, these parameters must be assessed anew. The goal of this study was to obtain accurate spin‐lattice (T1) relaxation times for the normal mouse brain at field strengths of 9.4 and 17.6 T. T1 relaxation times were determined for cortex, corpus callosum, caudate putamen, hippocampus, periaqueductal gray, lateral ventricle, and cerebellum and varied from 1651 ± 28 to 2449 ± 150 ms at 9.4 T and 1824 ± 101 to 2772 ± 235 ms at 17.6 T. A field strength–dependent increase of T1 relaxation times is shown. The SNR increase at 17.6 T is in good agreement with the expected SNR increase for a sample‐dominated noise regime. Magn Reson Med 58:390–395, 2007. © 2007 Wiley‐Liss, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.21313

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 36

Metadata

Authors
van de Ven, R. C. G., Hogers, B., van den Maagdenberg, A. M. J. M., de Groot, H. J. M., Ferrari, M. D., Frants, R. R., Poelmann, R. E., van der Weerd, L., & Kiihne, S. R.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
2007-07-24
Volume
58
Issue
2
Pages
390-395
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W2150252663
Cited by
36
References
3
FWCI
0.68
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.