The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
MR elastography of breast lesions: Understanding the solid/liquid duality can improve the specificity of contrast‐enhanced MR mammography
Open accessAbstract
The purpose of this analysis is to explore the potential diagnostic gain provided by the viscoelastic shear properties of breast lesions for the improvement of the specificity of contrast enhanced dynamic MR mammography (MRM). The assessment of viscoelastic properties is done via dynamic MR elastography (MRE) and it is demonstrated that the complex shear modulus of in vivo breast tissue follows within the frequency range of clinical MRE a power law behavior. Taking benefit of this frequency behavior, data are interpreted in the framework of the exact model for wave propagation satisfying the causality principle. This allows to obtain the exponent of the frequency power law from the complex shear modulus at one single frequency which is validated experimentally. Thereby, scan time is drastically reduced. It is observed that malignant tumors obtain larger exponents of the power law than benign tumors indicating a more liquid‐like behavior. The combination of the Breast Imaging Reporting and Data System (BIRADS) categorization obtained via MRM with viscoelastic information leads to a substantial rise in specificity. Analysis of 39 malignant and 29 benign lesions shows a significant diagnostic gain with an increase of about 20% in specificity at 100% sensitivity. Magn Reson Med, 2007. © 2007 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The microenvironment of the tumour–host interface
Liotta, L. A., & Kohn, E. C. (2001) · Nature · doi:10.1038/35077241 · Cited by 2,310
Magnetic Resonance Elastography by Direct Visualization of Propagating Acoustic Strain Waves
Muthupillai, R., Lomas, D. J., Rossman, P. J., Greenleaf, J. F., Manduca, A., & Ehman, R. L. (1995) · Science · doi:10.1126/science.7569924 · Cited by 2,116
On the Theory of Dispersion of X-Rays
de L. Kronig, R. (1926) · Journal of the Optical Society of America · doi:10.1364/josa.12.000547 · Cited by 1,987
ROC Methodology in Radiologic Imaging
METZ, C. E. (1986) · Investigative Radiology · doi:10.1097/00004424-198609000-00009 · Cited by 1,642
Regulation of matrix metalloproteinase expression in tumor invasion
Westermarck, J., & Kähäri, V. (1999) · The FASEB Journal · doi:10.1096/fasebj.13.8.781 · Cited by 1,494
Kuhl, C. K., Mielcareck, P., Klaschik, S., Leutner, C., Wardelmann, E., Gieseke, J., & Schild, H. H. (1999) · Radiology · doi:10.1148/radiology.211.1.r99ap38101 · Cited by 1,277
Breast Carcinoma: Effect of Preoperative Contrast-enhanced MR Imaging on the Therapeutic Approach
Fischer, U., Kopka, L., & Grabbe, E. (1999) · Radiology · doi:10.1148/radiology.213.3.r99dc01881 · Cited by 664
Generalized viscoelastic models: their fractional equations with solutions
Schiessel, H., Metzler, R., Blumen, A., & Nonnenmacher, T. F. (1995) · Journal of Physics A: Mathematical and General · doi:10.1088/0305-4470/28/23/012 · Cited by 629
Viscoelastic shear properties of in vivo breast lesions measured by MR elastography
Sinkus, R., Tanter, M., Xydeas, T., Catheline, S., Bercoff, J., & Fink, M. (2005) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2004.11.060 · Cited by 503
Self-citationHigh-resolution tensor MR elastography for breast tumour detection
Sinkus, R., Lorenzen, J., Schrader, D., Lorenzen, M., Dargatz, M., & Holz, D. (2000) · Physics in Medicine and Biology · doi:10.1088/0031-9155/45/6/317 · Cited by 481
Self-citationMR Elastography of Breast Cancer: Preliminary Results
McKnight, A. L., Kugel, J. L., Rossman, P. J., Manduca, A., Hartmann, L. C., & Ehman, R. L. (2002) · American Journal of Roentgenology · doi:10.2214/ajr.178.6.1781411 · Cited by 381
Imaging anisotropic and viscous properties of breast tissue by magnetic resonance‐elastography
Sinkus, R., Tanter, M., Catheline, S., Lorenzen, J., Kuhl, C., Sondermann, E., & Fink, M. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20355 · Cited by 380
Self-citationBoetes, C., Barentsz, J. O., Mus, R. D. M., van der Sluis, R. F., van Erning, L. J. T. O., Hendriks, J. H. C. L., Holland, R., & Ruys, S. H. (1994) · Radiology · doi:10.1148/radiology.193.3.7972823 · Cited by 377
Time scale and other invariants of integrative mechanical behavior in living cells
Fabry, B., Maksym, G. N., Butler, J. P., Glogauer, M., Navajas, D., Taback, N. A., Millet, E. J., & Fredberg, J. J. (2003) · Physical Review E · doi:10.1103/physreve.68.041914 · Cited by 376
Tissue characterization using magnetic resonance elastography: preliminary results*
Kruse, S. A., Smith, J. A., Lawrence, A. J., Dresner, M. A., Manduca, A., Greenleaf, J. F., Ehman, R. L., Kruse, S. A., Smith, J. A., Lawrence, A. J., et al. (2000) · Physics in Medicine and Biology · doi:10.1088/0031-9155/45/6/313 · Cited by 340
A model for longitudinal and shear wave propagation in viscoelastic media
Szabo, T. L., & Wu, J. (2000) · The Journal of the Acoustical Society of America · doi:10.1121/1.428630 · Cited by 274
Booij, H. C., & Thoone, G. P. J. M. (1982) · Rheologica Acta · doi:10.1007/bf01520701 · Cited by 264
Effects of Proteins, Blood Cells and Glucose on the Viscosity of Cerebrospinal Fluid
Bloomfield, I. G., Johnston, I. H., & Bilston, L. E. (1998) · Pediatric Neurosurgery · doi:10.1159/000028659 · Cited by 232
Dynamic image interpretation of MRI of the breast
Kuhl, C. K., & Schild, H. H. (2000) · Journal of Magnetic Resonance Imaging · doi:10.1002/1522-2586(200012)12:6<965::aid-jmri23>3.0.co;2-1 · Cited by 211
Classification of hypervascularized lesions in CE MR imaging of the breast
Baum, F., Fischer, U., Vosshenrich, R., & Grabbe, E. (2002) · European Radiology · doi:10.1007/s00330-001-1213-1 · Cited by 187
Viscoelastic characterization of in vitro canine tissue
Kiss, M. Z., Varghese, T., & Hall, T. J. (2004) · Physics in Medicine and Biology · doi:10.1088/0031-9155/49/18/002 · Cited by 172
Li, M., Zhou, J., Sasano, H., Suzuki, T., Zeitoun, K. M., & Bulun, S. E. (2001) · PubMed · Cited by 169
Visualizing tissue compliance with MR imaging
Plewes, D. B., Betty, I., Urchuk, S. N., & Soutar, I. (1995) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880050620 · Cited by 166
MR elastography of the breast:preliminary clinical results
Lorenzen, J., Sinkus, R., Lorenzen, M., Dargatz, M., Leussler, C., Röschmann, P., & Adam, G. (2002) · RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren · doi:10.1055/s-2002-32690 · Cited by 101
Self-citationMagnetic Resonance Elastography of the Breast
Xydeas, T., Siegmann, K., Sinkus, R., Krainick‐Strobel, U., Miller, S., & Claussen, C. D. (2005) · Investigative Radiology · doi:10.1097/01.rli.0000166940.72971.4a · Cited by 84
Self-citationMammography benefit in the Canadian National Breast Screening Study‐2: A model evaluation
Rijnsburger, A. J., van Oortmarssen, G. J., Boer, R., Draisma, G., To, T. M., Miller, A. B., & de Koning, H. J. (2004) · International Journal of Cancer · doi:10.1002/ijc.20143 · Cited by 52
Darstellung von Tumoren der weiblichen Brust mit MR-Elastographie
Lorenzen, J. (2001) · RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren · doi:10.1055/s-2001-10233 · Cited by 17
Cited by
Effects of extracellular matrix viscoelasticity on cellular behaviour
Chaudhuri, O., Cooper-White, J., Janmey, P. A., Mooney, D. J., & Shenoy, V. B. (2020) · Nature · doi:10.1038/s41586-020-2612-2 · Cited by 2,224
Fractional calculus models of complex dynamics in biological tissues
Magin, R. L. (2010) · Computers & Mathematics with Applications · doi:10.1016/j.camwa.2009.08.039 · Cited by 1,011
Fractional calculus in viscoelasticity: An experimental study
Meral, F. C., Royston, T. J., & Magin, R. (2010) · Communications in Nonlinear Science and Numerical Simulation · doi:10.1016/j.cnsns.2009.05.004 · Cited by 636
Imaging the elastic properties of tissue: the 20 year perspective
Parker, K. J., Doyley, M. M., & Rubens, D. J. (2011) · Physics in Medicine and Biology · doi:10.1088/0031-9155/56/1/r01 · Cited by 477
Matrix mechanical plasticity regulates cancer cell migration through confining microenvironments
Wisdom, K. M., Adebowale, K., Chang, J., Lee, J. Y., Nam, S., Desai, R., Rossen, N. S., Rafat, M., West, R. B., Hodgson, L., et al. (2018) · Nature Communications · doi:10.1038/s41467-018-06641-z · Cited by 426
Metadata
- Authors
- Sinkus, R., Siegmann, K., Xydeas, T., Tanter, M., Claussen, C., & Fink, M.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2007-10-29
- Volume
- 58
- Issue
- 6
- Pages
- 1135-1144
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2031795410
- Cited by
- 332
- References
- 27
- FWCI
- 11.17
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.