The DOI matches its Crossref record.
High-resolution tensor MR elastography for breast tumour detection
Open accessAbstract
MR elastography is a novel imaging technique for the visualization of elastic properties of tissue. It is expected that this method will have diagnostic value for the clarification of suspicious breast lesions. Low-frequency mechanical waves are coupled into the tissue and visualized via an MR sequence which is phase-locked to the mechanical excitation. Commonly, elasticity is assumed to be isotropic and reconstruction is performed in only two dimensions. The technique is extended to three dimensions such that the entire symmetric elasticity tensor is assessed. This is achieved by measuring different phases of the mechanical wave during one oscillatory cycle. Thereby it is possible to provide information about the anisotropy of the elasticity tensor. Finite-element simulations as well as phantom experiments are performed to demonstrate the feasibility of the method. Initial clinical results of a breast carcinoma are presented. The analysis of the eigenvalues of the elasticity tensor support the hypothesis that breast carcinoma might exhibit an anisotropic elasticity distribution. The surrounding benign tissue appears isotropic. Thereby new and additional diagnostic information is provided which might help in distinguishing between benign and malignant breast diseases.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Matrix Crosslinking Forces Tumor Progression by Enhancing Integrin Signaling
Levental, K. R., Yu, H., Kass, L., Lakins, J. N., Egeblad, M., Erler, J. T., Fong, S. F. T., Csiszar, K., Giaccia, A., Weninger, W., et al. (2009) · Cell · doi:10.1016/j.cell.2009.10.027 · Cited by 4,101
Meat quality assessment using biophysical methods related to meat structure
Damez, J.-L., & Clerjon, S. (2008) · Meat Science · doi:10.1016/j.meatsci.2008.05.039 · Cited by 280
Initial in vivo experience with steady‐state subzone‐based MR elastography of the human breast
Van Houten, E. E. W., Doyley, M. M., Kennedy, F. E., Weaver, J. B., & Paulsen, K. D. (2003) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.10232 · Cited by 224
Elastography imaging: the 30 year perspective
Ormachea, J., & Parker, K. J. (2020) · Physics in Medicine & Biology · doi:10.1088/1361-6560/abca00 · Cited by 104
Brain mechanical property measurement using MRE with intrinsic activation
Weaver, J. B., Pattison, A. J., McGarry, M. D., Perreard, I. M., Swienckowski, J. G., Eskey, C. J., Lollis, S. S., & Paulsen, K. D. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/22/7275 · Cited by 102
Metadata
- Authors
- Sinkus, R., Lorenzen, J., Schrader, D., Lorenzen, M., Dargatz, M., & Holz, D.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2000-05-19
- Volume
- 45
- Issue
- 6
- Pages
- 1649-1664
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2026786928
- Cited by
- 481
- References
- 0
- FWCI
- 14.06
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: High-resolution tensor MR elastography for breast tumour detection. https://app.cochat.ai/papers/10.1088/0031-9155/45/6/317
- The paper
- Sinkus, R., Lorenzen, J., Schrader, D., Lorenzen, M., Dargatz, M., & Holz, D. (2000). High-resolution tensor MR elastography for breast tumour detection. Physics in Medicine and Biology. https://doi.org/10.1088/0031-9155/45/6/317
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.