The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Fast multislice mapping of the myelin water fraction using multicompartment analysis of T decay at 3T: A preliminary postmortem study
Abstract
Quantitative mapping of the myelin water content can provide significant insight into the pathophysiology of several white matter diseases, such as multiple sclerosis and leukoencephalopathies, and can potentially become a useful clinical tool for early diagnosis of these diseases. In this study, multicompartment analysis of T decay (MCAT2*) was used for the quantitative mapping of myelin water fraction (MWF). T decay of each voxel at multiple slice locations was acquired in fixed human brains using a multigradient‐echo (MGRE) pulse sequence with alternating readout gradient polarities. Compared to prior techniques using Carr‐Purcell‐Meiboom‐Gill (CPMG) acquisition, the MGRE acquisition approach has: 1) a very short first echo time (≈2 ms) and echo‐spacing (≈1 ms), which allows for the acquisition of multiple sampling points during the fast decay of the myelin water signal; 2) a low RF duty cycle, which is especially important for achieving acceptable specific absorption rate (SAR) levels at high field strengths. Multicompartment analysis was then applied to the T decay in each pixel using a 3‐pool model of white matter to detect the signal arising from the myelin water, myelinated axonal water, and mixed water compartments. Magn Reson Med 58:865–870, 2007. © 2007 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A pathology–MRI study of the short-T2 component in formalin-fixed multiple sclerosis brain
Moore, G. R. W., Leung, E., MacKay, A. L., Vavasour, I. M., Whittall, K. P., Cover, K. S., Li, D. K. B., Hashimoto, S. A., Oger, J., Sprinkle, T. J., et al. (2000) · Neurology · doi:10.1212/wnl.55.10.1506 · Cited by 185
Cited by
MRI‐based myelin water imaging: A technical review
Alonso‐Ortiz, E., Levesque, I. R., & Pike, G. B. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25198 · Cited by 285
Magnetic Resonance of Myelin Water: An in vivo Marker for Myelin
MacKay, A. L., & Laule, C. (2016) · Brain Plasticity · doi:10.3233/bpl-160033 · Cited by 284
Iron, myelin, and the brain: neuroimaging meets neurobiology
Möller, H. E., Bossoni, L., Connor, J. R., Crichton, R. R., Does, M. D., Ward, R. J., Zecca, L., Zucca, F. A., & Ronen, I. (2019) · Trends in Neurosciences · doi:10.1016/j.tins.2019.03.009 · Cited by 207
Postmortem MRI of human brain hemispheres: T 2 relaxation times during formaldehyde fixation
Dawe, R. J., Bennett, D. A., Schneider, J. A., Vasireddi, S. K., & Arfanakis, K. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21909 · Cited by 162
Promise and pitfalls of g-ratio estimation with MRI
Campbell, J. S. W., Leppert, I. R., Narayanan, S., Boudreau, M., Duval, T., Cohen-Adad, J., Pike, G. B., & Stikov, N. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2017.08.038 · Cited by 129
Metadata
- Authors
- Du, Y. P., Chu, R., Hwang, D., Brown, M. S., Kleinschmidt‐DeMasters, B. K., Singel, D., & Simon, J. H.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2007-10-29
- Volume
- 58
- Issue
- 5
- Pages
- 865-870
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2148654762
- Cited by
- 186
- References
- 1
- FWCI
- 3.19
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Fast multislice mapping of the myelin water fraction using multicompartment analysis of T decay at 3T: A preliminary postmortem study. https://app.cochat.ai/papers/10.1002/mrm.21409
- The paper
- Du, Y. P., Chu, R., Hwang, D., Brown, M. S., Kleinschmidt‐DeMasters, B. K., Singel, D., & Simon, J. H. (2007). Fast multislice mapping of the myelin water fraction using multicompartment analysis of T decay at 3T: A preliminary postmortem study. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.21409
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.