Cited by 162Advanced MRI Techniques and ApplicationsAdvanced Neuroimaging Techniques and ApplicationsNMR spectroscopy and applications

Postmortem MRI of human brain hemispheres: T 2 relaxation times during formaldehyde fixation

Open access
Dawe, Robert J., Bennett, David A., Schneider, Julie A., Vasireddi, Sunil K., Arfanakis, Konstantinos·2009·Magnetic Resonance in Medicine

Abstract

Unlike in vivo imaging, postmortem MRI allows for invasive examination of the tissue specimen immediately after the MR scan. However, natural tissue decomposition and chemical fixation cause the postmortem tissue's MRI properties to be different from those found in vivo. Moreover, these properties change as postmortem fixation time elapses. The goal of this study was to characterize the T 2 relaxation changes that occur over time in cadaveric human brain hemispheres during fixation. Five hemispheres immersed in formaldehyde solution were scanned on a weekly basis for 3 months postmortem, and once again at 6 months postmortem. The T 2 relaxation times were measured throughout the hemispheres. Over time, T 2 values near the edges of the hemispheres decreased rapidly after death, while T 2 values of deep tissue decreased more slowly. This difference is likely due to the relatively large distance from the hemisphere surface, and other barriers limiting diffusion of formaldehyde molecules to deep tissues. In addition, T 2 values in deep tissue did not continuously decay to a plateau, but instead reached a minimum and then increased to a plateau. This final increase may be due to the effects of prolonged tissue decomposition, a hypothesis that is supported by numerical simulations of the fixation process. Magn Reson Med, 2009. © 2009 Wiley‐Liss, Inc.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.21909

Cites

36 of 36 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Different samples (or different anatomical areas within the same sample) are not affected homogeneously by preparation steps such as fixation or antibody penetration, which poses challenges in particular for between-subject validation designs.

    “Moreover, it is known that different samples (or different anatomical areas within the same sample) are not affected homogeneously by preparation steps such as fixation or antibody penetration (Dawe, Bennett, Schneider, Vasireddi, Arfanakis, 2009, Seehaus, Roebroeck, Bastiani, Fonseca, 2015), which poses challenges in particular for between-subject validation designs.”

    From Can MRI measure myelin? Systematic review, qualitative assessment, and meta-analysis of studies validating microstructural imaging with myelin histology (2021) · cites this paper as Dawe, Bennett, Schneider, Vasireddi, Arfanakis, 2009

    Split into 2 atoms — 1 confirmed, 1 partially supported, 0 disputed, 0 misattributed, 0 unverifiable. Expand the claim to see per-atom verdicts.

    Experimental — accuracy not yet measured
  • Longitudinal studies investigating tissue fixation report spatially and temporally varying effects on relaxation rates, MWF and also MP.

    “Longitudinal studies investigating tissue fixation report spatially and temporally varying effects on relaxation rates, MWF and also MP (Dawe, Bennett, Schneider, Vasireddi, Arfanakis, 2009, Seifert, 2019, Shatl, Uddin, Matsuda, Figley, 2018).”

    From Can MRI measure myelin? Systematic review, qualitative assessment, and meta-analysis of studies validating microstructural imaging with myelin histology (2021) · cites this paper as Dawe, Bennett, Schneider, Vasireddi, Arfanakis, 2009

    The Conclusions (page not available) report that T2 relaxation during formaldehyde fixation varies with both time and position within human brain hemispheres. The paper does not report fixation effects on myelin water fraction (MWF) or MP; its Discussion describes analysis of different water environments as future work. Thus, this source supports the relaxation component of the multiply cited sentence, but not the full list of measures. (LLM, conf=0.88)

    Experimental — accuracy not yet measured

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Research works printed but not linked: 2

  1. [7]Moore GR Leung E MacKay AL Vavasour IM Whittall KP Cover KS Li DK Hashimoto SA Oger J Sprinkle TJ Paty DW Neurology 2000 55 1506 1510 11094105
  2. [31]Baker JR Primary fixatives considered separately 2. Non-coagulants Baker JR Principles of biological microtechnique New York Wiley 1958 31 43

Cited by

Sorted by citations

Authors
Dawe, R. J., Bennett, D. A., Schneider, J. A., Vasireddi, S. K., & Arfanakis, K.
Affiliations
  • Illinois Institute of Technology (US)
  • Rush University Medical Center (US)
Corresponding author
Arfanakis, Konstantinos
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
2009-02-02
Volume
61
Issue
4
Pages
810-818
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W2135249414
Cited by
162
References
36
Citations by year
2026: 7 · 2025: 12 · 2024: 14 · 2023: 7 · 2022: 10 · 2021: 13 · 2020: 14 · 2019: 11 · 2018: 12 · 2017: 6 · 2016: 9 · 2015: 10 · 2014: 9 · 2013: 8 · 2012: 3
FWCI
5.04
Type
journal article
Language
en
Open access
Locations
  • Magnetic Resonance in Medicine (publishedVersion)
  • PubMed (publishedVersion)
  • Europe PMC (PubMed Central) (acceptedVersion)
  • PubMed Central (acceptedVersion)
Funders
National Institute on Aging (R01AG017917, P30-AG 10161, R01‐AG17917, R01 AG15819, R01AG015819, P30AG010161)
Topics
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced MRI Techniques and Applications
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced Neuroimaging Techniques and Applications
  • Physical Sciences › Physics and Astronomy › Nuclear and High Energy Physics › NMR spectroscopy and applications
Keywords
postmortem MRI, T2 relaxation time, formalin fixation, tissue decomposition, fixation duration
MeSH terms
Brain, Fixatives, Formaldehyde, Humans, Longitudinal Studies, Magnetic Resonance Imaging, Postmortem Changes

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review