The DOI matches its Crossref record.
Cardiac metabolism measured noninvasively by hyperpolarized 13C MRI
Open accessAbstract
Pyruvate is included in the energy production of the heart muscle and is metabolized into lactate, alanine, and CO 2 in equilibrium with HCO. The aim of this study was to evaluate the feasibility of using 13 C hyperpolarization enhanced MRI to monitor pyruvate metabolism in the heart during an ischemic episode. The left circumflex artery of pigs (4 months, male, 29–34 kg) was occluded for 15 or 45 min followed by 2 hr of reperfusion. Pigs were examined by 13 C chemical shift imaging following intravenous injection of 1‐13 C pyruvate. 13 C chemical shift MR imaging was used in order to visualize the local concentrations of the metabolites. After a 15‐min occlusion (no infarct) the bicarbonate signal level in the affected area was reduced (25–44%) compared with the normal myocardium. Alanine signal level was normal. After a 45‐min occlusion (infarction) the bicarbonate signal was almost absent (0.2–11%) and the alanine signal was reduced (27–51%). Due to image‐folding artifacts the data obtained for lactate were inconclusive. These studies demonstrate that cardiac metabolic imaging with hyperpolarized 1‐13 C‐pyruvate is feasible. The changes in concentrations of the metabolites within a minute after injection can be detected and metabolic maps constructed. Magn Reson Med 59:1005–1013, 2008. © 2008 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Kurhanewicz, J., Vigneron, D. B., Brindle, K., Chekmenev, E. Y., Comment, A., Cunningham, C. H., DeBerardinis, R. J., Green, G. G., Leach, M. O., Rajan, S. S., et al. (2011) · Neoplasia · doi:10.1593/neo.101102 · Cited by 681
Pros and cons of ultra-high-field MRI/MRS for human application
Ladd, M. E., Bachert, P., Meyerspeer, M., Moser, E., Nagel, A. M., Norris, D. G., Schmitter, S., Speck, O., Straub, S., & Zaiss, M. (2018) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/j.pnmrs.2018.06.001 · Cited by 544
Hyperpolarized 13 C Metabolic MRI of the Human Heart: Initial Experience
Cunningham, C. H., Lau, J. Y. C., Chen, A. P., Geraghty, B. J., Perks, W. J., Roifman, I., Wright, G. A., & Connelly, K. A. (2016) · Circulation Research · doi:10.1161/circresaha.116.309769 · Cited by 364
Gallagher, F. A., Kettunen, M. I., Hu, D.-E., Jensen, P. R., Zandt, R. I. ‘., Karlsson, M., Gisselsson, A., Nelson, S. K., Witney, T. H., Bohndiek, S. E., et al. (2009) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0911447106 · Cited by 301
Self-citationHall, H., Cuellar-Baena, S., Dahlberg, C., in’t Zandt, R., Denisov, V., & Kirik, D. (2011) · Current Topics in Behavioral Neurosciences · doi:10.1007/7854_2011_166 · Cited by 17
Metadata
- Authors
- Golman, K., Petersson, J. S., Magnusson, P., Johansson, E., Åkeson, P., Chai, C., Hansson, G., & Månsson, S.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2008-04-21
- Volume
- 59
- Issue
- 5
- Pages
- 1005-1013
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2116981594
- Cited by
- 216
- References
- 0
- FWCI
- 6.93
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Cardiac metabolism measured noninvasively by hyperpolarized 13C MRI. https://app.cochat.ai/papers/10.1002/mrm.21460
- The paper
- Golman, K., Petersson, J. S., Magnusson, P., Johansson, E., Åkeson, P., Chai, C., Hansson, G., & Månsson, S. (2008). Cardiac metabolism measured noninvasively by hyperpolarized 13C MRI. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.21460
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.