NMR probes for measuring magnetic fields and field dynamics in MR systems
Open accessThe DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Abstract
High‐resolution magnetic field probes based on pulsed liquid‐state NMR are presented. Static field measurements with an error of 10 nanotesla or less at 3 tesla are readily obtained in 100 ms. The further ability to measure dynamic magnetic fields results from using small (∼1 μL) droplets of MR‐active liquid surrounded by susceptibility‐matched materials. The consequent high field homogeneity allows free induction decay signals lasting 100 ms or more to be readily achieved. The small droplet dimensions allow the magnetic field to be measured even in the presence of large gradients. Highly sensitive detection yields sufficient SNR to follow the relevant field evolution without signal averaging and at bandwidths up to hundreds of kHz. Transient, nonreproducible effects and drifts are thus readily monitored. The typical application of k‐space trajectory mapping has been demonstrated. Potential further applications include characterization, tuning, and maintenance of gradient systems as well as the mapping of the static field distribution of MRI magnets. Connection of the probes to a standard MR spectrometer is similar to that used for imaging coils. Magn Reson Med 60:176–186, 2008. © 2008 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
CRC Handbook of Chemistry and Physics
(2014) · doi:10.1201/b17118 · Cited by 57,706
Table of Integrals, Series, and Products
(1980) · Elsevier eBooks · doi:10.1016/c2013-0-10754-4 · Cited by 18,782
The Principles of Nuclear Magnetism
Abragam, A., & Hebel, L. C. (1961) · American Journal of Physics · doi:10.1119/1.1937646 · Cited by 15,792
Electrodynamics of Continuous Media
Landau, L. D., Lifshitz, E. M., & King, A. L. (1961) · American Journal of Physics · doi:10.1119/1.1937882 · Cited by 10,997
Table of Integrals, Series, and Products
(2000) · Elsevier eBooks · doi:10.1016/b978-0-12-294757-5.x5000-4 · Cited by 8,408
CODATA recommended values of the fundamental physical constants: 2010
Mohr, P. J., Taylor, B. N., & Newell, D. B. (2012) · Reviews of Modern Physics · doi:10.1103/revmodphys.84.1527 · Cited by 2,441
Multi-planar image formation using NMR spin echoes
Mansfield, P. (1977) · Journal of Physics C: Solid State Physics · doi:10.1088/0022-3719/10/3/004 · Cited by 1,813
Schenck, J. F. (1996) · Medical Physics · doi:10.1118/1.597854 · Cited by 1,522
Electrodynamics: Continuous Media
Eringen, A. C. (2005) · Encyclopedia of Condensed Matter Physics · doi:10.1016/b0-12-369401-9/00438-1 · Cited by 1,024
Lenz, J. E. (1990) · Proceedings of the IEEE · doi:10.1109/5.56910 · Cited by 736 · cited 3×
“Such inhomogeneous broadening violates Equation [1], which accounts only for a single relevant field strength at any given time.”
Background
Cited by
Degen, C. L., Reinhard, F., & Cappellaro, P. (2017) · Reviews of Modern Physics · doi:10.1103/revmodphys.89.035002 · Cited by 4,045
Nitrogen-Vacancy Centers in Diamond: Nanoscale Sensors for Physics and Biology
Schirhagl, R., Chang, K., Loretz, M., & Degen, C. L. (2014) · Annual Review of Physical Chemistry · doi:10.1146/annurev-physchem-040513-103659 · Cited by 1,608
Metadata
- Authors
- De Zanche, N., Barmet, C., Nordmeyer‐Massner, J. A., & Pruessmann, K. P.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2008-06-25
- Volume
- 60
- Issue
- 1
- Pages
- 176-186
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W1979051347
- Cited by
- 214
- References
- 27
- FWCI
- 5.02
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.