CoChat

Three‐dimensional high‐resolution magnetic resonance spectroscopic imaging for absolute quantification of 31P metabolites in human liver

Open access
Chmelík, M., Schmid, A. I., Gruber, S., Szendroedi, J., Krššák, M., Trattnig, S., Moser, E., Roden, M. · 2008 · Magnetic Resonance in Medicine
Cited by 53

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Liver dysfunction correlates with alterations of intracellular concentrations of 31 P metabolites. Localization and absolute quantification should help to trace regional hepatic metabolism. An improved protocol for the absolute quantification of 31 P metabolites in vivo in human liver was developed by employing three‐dimensional (3D) k‐space weighted spectroscopic imaging (MRSI) with B1‐insensitive adiabatic excitation. The protocol allowed for high spatial resolution of 17.8 ± 0.22 cm 3 in 34 min at 3 T. No pulse adjustment prior to MRSI measurement was necessary due to adiabatic excitation. The protocol geometry was identical for all measurements so that one calibration data set, acquired from phantom replacement measurement, was applied for all quantifications. The protocol was tested in 10 young, healthy volunteers, for whom 57 ± 7 spectra were quantified. Concentrations per liter of liver volume (reproducibilities) were 2.24 ± 0.10 mmol/L (1.8%) for phosphomonoesters (PME), 1.37 ± 0.07 mmol/L (7.9%) for inorganic phosphate (Pi), 11.40 ± 0.96 mmol/L (2.9%) for phosphodiesters (PDE), and 2.14 ± 0.10 mmol/L (1.6%) for adenosine triphosphate (ATP), respectively. Taken together, this approach provides fast, simple, and reproducible high‐resolution absolute quantification and detailed mapping of the spatial distribution of hepatic 31 P metabolites. This method allows for examination of regional deviations of energy metabolism in human liver diseases. Magn Reson Med 60:796–802, 2008. © 2008 Wiley‐Liss, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.21762

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 53

Metadata

Authors
Chmelík, M., Schmid, A. I., Gruber, S., Szendroedi, J., Krššák, M., Trattnig, S., Moser, E., & Roden, M.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
2008-09-24
Volume
60
Issue
4
Pages
796-802
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W2052729160
Cited by
53
References
1
FWCI
2.87
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.