The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Quantitative 2D and 3D phase contrast MRI: Optimized analysis of blood flow and vessel wall parameters
Abstract
Quantification of CINE phase contrast (PC)‐MRI data is a challenging task because of the limited spatiotemporal resolution and signal‐to‐noise ratio (SNR). The method presented in this work combines B‐spline interpolation and Green's theorem to provide optimized quantification of blood flow and vessel wall parameters. The B‐spline model provided optimal derivatives of the measured three‐directional blood velocities onto the vessel contour, as required for vectorial wall shear stress (WSS) computation. Eight planes distributed along the entire thoracic aorta were evaluated in a 19‐volunteer study using both high‐spatiotemporal‐resolution planar two‐dimensional (2D)‐CINE‐PC (∼1.4 × 1.4 mm 2/24.4 ms) and lower‐resolution 3D‐CINE‐PC (∼2.8 × 1.6 × 3 mm 3/48.6 ms) with three‐directional velocity encoding. Synthetic data, error propagation, and interindividual, intermodality, and interobserver variability were used to evaluate the reliability and reproducibility of the method. While the impact of MR measurement noise was only minor, the limited resolution of PC‐MRI introduced systematic WSS underestimations. In vivo data demonstrated close agreement for flow and WSS between 2D‐ and 3D‐CINE‐PC as well as observers, and confirmed the reliability of the method. WSS analysis along the aorta revealed the presence of a circumferential WSS component accounting for 10–20%. Initial results in a patient with atherosclerosis suggest the potential of the method for understanding the formation and progression of cardiovascular diseases. Magn Reson Med 60:1218–1231, 2008. © 2008 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Flow-mediated endothelial mechanotransduction
Davies, P. F. (1995) · Physiological Reviews · doi:10.1152/physrev.1995.75.3.519 · Cited by 2,802
Cited by
Markl, M., Frydrychowicz, A., Kozerke, S., Hope, M., & Wieben, O. (2012) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.23632 · Cited by 788
Self-citationBicuspid Aortic Valve Is Associated With Altered Wall Shear Stress in the Ascending Aorta
Barker, A. J., Markl, M., Bürk, J., Lorenz, R., Bock, J., Bauer, S., Schulz-Menger, J., & von Knobelsdorff-Brenkenhoff, F. (2012) · Circulation: Cardiovascular Imaging · doi:10.1161/circimaging.112.973370 · Cited by 454
Self-citationPeiffer, V., Sherwin, S. J., & Weinberg, P. D. (2013) · Cardiovascular Research · doi:10.1093/cvr/cvt044 · Cited by 379
Endothelial Cell Sensing of Flow Direction
Wang, C., Baker, B. M., Chen, C. S., & Schwartz, M. A. (2013) · Arteriosclerosis, Thrombosis, and Vascular Biology · doi:10.1161/atvbaha.113.301826 · Cited by 294
Borger, M. A., Fedak, P. W. M., Stephens, E. H., Gleason, T. G., Girdauskas, E., Ikonomidis, J. S., Khoynezhad, A., Siu, S. C., Verma, S., Hope, M. D., et al. (2018) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2018.02.115 · Cited by 287
Self-citation
Metadata
- Authors
- Stalder, A. F., Russe, M. F., Frydrychowicz, A., Bock, J., Hennig, J., & Markl, M.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2008-10-27
- Volume
- 60
- Issue
- 5
- Pages
- 1218-1231
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2068859764
- Cited by
- 474
- References
- 1
- FWCI
- 13.62
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.