Reproducibility assessment of metabolic variables characterizing muscle energetics in Vivo: A 31P‐MRS study
Open accessThe DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
The purpose of the present study was to assess the reliability of metabolic parameters measured using 31 P magnetic resonance spectroscopy (31 P MRS) during two standardized rest‐exercise‐recovery protocols. Twelve healthy subjects performed the standardized protocols at two different intensities; i.e., a moderate intensity (MOD) repeated over a two‐month period and heavy intensity (HEAVY) repeated over a year's time. Test‐retest reliability was analyzed using coefficient of variation (CV), limits of agreement (LOA), and intraclass correlation coefficients (ICC). During exercise and recovery periods, most of the metabolic parameters exhibited a good reliability. The CVs of individual concentration of phosphocreatine ([PCr]), concentration of adenosine diphosphate ([ADP]), and pH values recorded at end of the HEAVY exercise were lower than 15%. The CV calculated for the rate of PCr resynthesis and the maximal oxidative capacity were less than 13% during the HEAVY protocol. Inferred parameters such as oxidative and total adenosine triphosphate (ATP) production rates exhibited a good reliability (ICC ≈ 0.7; CV < 15% during the HEAVY protocol). Our results demonstrated that measurement error using 31 P‐MRS during a standardized exercise was low and that biological variability accounted for the vast majority of the measurement variability. In addition, the corresponding metabolic measurements can reliably be used for longitudinal studies performed even over a long period of time. Magn Reson Med, 2009. © 2009 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Measures of Reliability in Sports Medicine and Science
Hopkins, W. G. (2000) · Sports Medicine · doi:10.2165/00007256-200030010-00001 · Cited by 4,635 · cited 1×
“Given the sensitivity of ICC to the heterogeneity of values between subjects (48), the low ICC value for pH changes was probably due to the low range of pH measurements.”
BackgroundArnold, D. L., Matthews, P. M., & Radda, G. K. (1984) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910010303 · Cited by 442
Mammalian skeletal muscle fibers distinguished by contents of phosphocreatine, ATP, and Pi
Kushmerick, M. J., Moerland, T. S., & Wiseman, R. W. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.16.7521 · Cited by 301
McCully, K. K., Fielding, R. A., Evans, W. J., Leigh, J. S., & Posner, J. D. (1993) · Journal of Applied Physiology · doi:10.1152/jappl.1993.75.2.813 · Cited by 288
Reliability of techniques to assess human neuromuscular function in vivo
Clark, B. C., Cook, S. B., & Ploutz-Snyder, L. L. (2007) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2005.11.008 · Cited by 107 · cited 2×
“(39), we used the Bland and Altman plot in order to identify heteroscedasticity; i.”
BackgroundMethodBendahan, D., Desnuelle, C., Vanuxem, D., Confort-Gouny, S., Figarella-Branger, D., Pellissier, J. F., Kozak-Ribbens, G., Pouget, J., Serratrice, G., & Cozzone, P. J. (1992) · Neurology · doi:10.1212/wnl.42.6.1203 · Cited by 104
Self-citation
Cited by
Nolfi-Donegan, D., Braganza, A., & Shiva, S. (2020) · Redox Biology · doi:10.1016/j.redox.2020.101674 · Cited by 1,488
“metabolites such as choline-containing compounds, creatine, glucose, alanine and lactate by measuring the resonance of MR-visible isotopes [32].”
BackgroundLanza, I. R., Bhagra, S., Nair, K. S., & Port, J. D. (2011) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.22733 · Cited by 103
Li, M., Chen, F., Wang, H., Wu, W., Zhang, X., Tian, C., Yu, H., Liu, R., Zhu, B., Zhang, B., et al. (2016) · PeerJ · doi:10.7717/peerj.2259 · Cited by 8
Metadata
- Authors
- Layec, G., Bringard, A., Le Fur, Y., Vilmen, C., Micallef, J., Perrey, S., Cozzone, P. J., & Bendahan, D.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2009-09
- Volume
- 62
- Issue
- 4
- Pages
- 840-854
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2047931391
- Cited by
- 75
- References
- 7
- FWCI
- 3.05
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Reproducibility assessment of metabolic variables characterizing muscle energetics in Vivo: A 31P‐MRS study. https://app.cochat.ai/papers/10.1002/mrm.22085
- The paper
- Layec, G., Bringard, A., Le Fur, Y., Vilmen, C., Micallef, J., Perrey, S., Cozzone, P. J., & Bendahan, D. (2009). Reproducibility assessment of metabolic variables characterizing muscle energetics in Vivo: A 31P‐MRS study. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.22085
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.