CoChat

Characterizing healthy and diseased white matter using quantitative magnetization transfer and multicomponent T2 relaxometry: A unified view via a four‐pool model

Levesque, Ives R., Pike, G. Bruce · 2009 · Magnetic Resonance in Medicine
Cited by 82

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Nuclear magnetic resonance relaxation and magnetization transfer in cerebral white matter can be described using a four‐pool model: two for water protons (in separate myelin and intra/extracellular compartments) and two for protons associated with the lipids and proteins of biologic membranes (of myelin and nonmyelin semisolids). This model was used to gain insight into the observations from multicomponent quantitative T2 relaxometry and quantitative magnetization transfer imaging, both based on simplified white matter models and experimentally feasible in vivo. Using a set of coupled Bloch equations describing the behavior of the magnetization in a four‐pool model of white matter, simulations of the quantitative T2 relaxometry and quantitative magnetization transfer imaging techniques were performed. Pathology‐inspired modifications were made to the four‐pool model to gauge their impact on quantitative T2 relaxometry and quantitative magnetization transfer imaging observations. Our results show that changes in the rate of water movement between microanatomic compartments may impact otherwise stable quantitative T2 relaxometry observations; that the measure of the quantitative magnetization transfer imaging–based semisolid pool population is robust, despite the presence of two distinct semisolid components; and that quantitative magnetization transfer imaging compartment size estimates are not influenced by changes in the T2 of the intra/extracellular water pool. The four‐pool model, while impractical for in vivo characterization, yields important insight into the interpretation of changes observed with these quantitative MRI methods based on simplified models of white matter. Magn Reson Med, 2009. © 2009 Wiley‐Liss, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.22131

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

Metadata

Authors
Levesque, I. R., & Pike, G. B.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
2009-10-26
Volume
62
Issue
6
Pages
1487-1496
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W2042564460
Cited by
82
References
2
FWCI
3.29
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.