The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Optimal radiofrequency and gradient spoiling for improved accuracy of T1 and B1 measurements using fast steady‐state techniques
Open accessAbstract
Variable flip angle T1 mapping and actual flip‐angle imaging B1 mapping are widely used quantitative MRI methods employing radiofrequency spoiled gradient‐echo pulse sequences. Incomplete elimination of the transverse magnetization in these sequences has been found to be a critical source of T1 and B1 measurement errors. In this study, comprehensive theoretical analysis of spoiling‐related errors in variable flip angle and actual flip‐angle imaging methods was performed using the combined isochromat summation and diffusion propagator model and validated by phantom experiments. The key theoretical conclusion is that correct interpretation of spoiling phenomena in fast gradient‐echo sequences requires accurate consideration of the diffusion effect. A general strategy for improvement of T1 and B1 measurement accuracy was proposed based on the strong spoiling regimen, where diffusion‐modulated spatial averaging of isochromats becomes a dominant factor determining magnetization evolution. Practical implementation of strongly spoiled variable flip angle and actual flip‐angle imaging techniques requires sufficiently large spoiling gradient areas (AG) in combination with optimal radiofrequency phase increments (ϕ 0). Optimal regimens providing <2% relative T1 and B1 measurement errors in a variety of tissues were theoretically derived for prospective in vivo variable flip angle (pulse repetition time = 15–20 ms, AG = 280–450 mT·ms/m, ϕ 0 = 169°) and actual flip‐angle imaging (pulse repetition time 1/pulse repetition time 2 = 20/100 ms, AG 1/AG 2 = 450/2250 mT·ms/m, ϕ 0 = 39°) applications based on 25 mT/m maximal available gradient strength. Magn Reson Med 63:1610–1626, 2010. © 2010 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
T1, T2 relaxation and magnetization transfer in tissue at 3T
Stanisz, G. J., Odrobina, E. E., Pun, J., Escaravage, M., Graham, S. J., Bronskill, M. J., & Henkelman, R. M. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20605 · Cited by 1,266
Diffusion tensor imaging of lesions and normal-appearing white matter in multiple sclerosis
Werring, D. J., Clark, C. A., Barker, G. J., Thompson, A. J., & Miller, D. H. (1999) · Neurology · doi:10.1212/wnl.52.8.1626 · Cited by 621
Stevenson, V. L., Parker, G. J. M., Barker, G. J., Birnie, K., Tofts, P. S., Miller, D. H., & Thompson, A. J. (2000) · Journal of the Neurological Sciences · doi:10.1016/s0022-510x(00)00339-7 · Cited by 126
Cited by
Quantitative multi-parameter mapping of R1, PD*, MT, and R2* at 3T: a multi-center validation
Weiskopf, N., Suckling, J., Williams, G., Correia, M. M., Inkster, B., Tait, R., Ooi, C., Bullmore, E. T., & Lutti, A. (2013) · Frontiers in Neuroscience · doi:10.3389/fnins.2013.00095 · Cited by 538
Alexander, A. L., Hurley, S. A., Samsonov, A. A., Adluru, N., Hosseinbor, A. P., Mossahebi, P., Tromp, D. P. M., Zakszewski, E., & Field, A. S. (2011) · Brain Connectivity · doi:10.1089/brain.2011.0071 · Cited by 449
Lifespan maturation and degeneration of human brain white matter
Yeatman, J. D., Wandell, B. A., & Mezer, A. A. (2014) · Nature Communications · doi:10.1038/ncomms5932 · Cited by 432
Using high-resolution quantitative mapping of R1 as an index of cortical myelination
Lutti, A., Dick, F., Sereno, M. I., & Weiskopf, N. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.06.005 · Cited by 346
On the accuracy of T1 mapping: Searching for common ground
Stikov, N., Boudreau, M., Levesque, I. R., Tardif, C. L., Barral, J. K., & Pike, G. B. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25135 · Cited by 285
Metadata
- Authors
- Yarnykh, V. L.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2010-05-21
- Volume
- 63
- Issue
- 6
- Pages
- 1610-1626
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W1995773861
- Cited by
- 170
- References
- 3
- FWCI
- 8.68
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Optimal radiofrequency and gradient spoiling for improved accuracy of T1 and B1 measurements using fast steady‐state techniques. https://app.cochat.ai/papers/10.1002/mrm.22394
- The paper
- Yarnykh, V. L. (2010). Optimal radiofrequency and gradient spoiling for improved accuracy of T1 and B1 measurements using fast steady‐state techniques. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.22394
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.