High‐resolution magnetization‐prepared 3D‐FLAIR imaging at 7.0 Tesla
Open accessThe DOI matches its Crossref record.
Abstract
The aim of the present study is to develop a submillimeter volumetric (three‐dimensional) fluid‐attenuated inversion recovery sequence at 7T. Implementation of the fluid‐attenuated inversion recovery sequence is difficult as increased T1 weighting from prolonged T1 constants at 7T dominate the desired T2 contrast and yield suboptimal signal‐to‐noise ratio. Magnetization preparation was used to reduce T1 weighting and improve the T2 weighting. Also, practical challenges limit the implementation. Long refocusing trains with low flip angles were used to mitigate the specific absorption rate constraints. This resulted in a three‐dimensional magnetization preparation fluid‐attenuated inversion recovery sequence with 0.8 × 0.8 × 0.8 = 0.5 mm 3 resolution in a clinically acceptable scan time. The contrast‐to‐noise ratio between gray matter and white matter (contrast‐to‐noise ratio = signal‐to‐noise ratio [gray matter] − signal‐to‐noise ratio [white matter]) increased from 12 ± 9 without magnetization preparation to 28 ± 8 with magnetization preparation (n = 12). The signal‐to‐noise ratio increased for white matter by 13 ± 6% and for gray matter by 48 ± 15%. In conclusion, three‐dimensional fluid‐attenuated inversion recovery with high resolution and full brain coverage is feasible at 7T. Magnetization preparation reduces the T1 weighting, thereby improving the T2 weighted contrast and signal‐to‐noise ratio. Magn Reson Med, 2010. © 2010 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Optimized three‐dimensional fast‐spin‐echo MRI
Mugler, J. P. (2014) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.24542 · Cited by 376
Clinical applications of 7T MRI in the brain
van der Kolk, A. G., Hendrikse, J., Zwanenburg, J. J. M., Visser, F., & Luijten, P. R. (2013) · European Journal of Radiology · doi:10.1016/j.ejrad.2011.07.007 · Cited by 268
Self-citationIn Vivo Detection of Cerebral Cortical Microinfarcts with High-Resolution 7T MRI
van Veluw, S. J., Zwanenburg, J. J., Engelen-Lee, J., Spliet, W. G., Hendrikse, J., Luijten, P. R., & Biessels, G. J. (2013) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.2012.196 · Cited by 193
Self-citation7‐T MR—from research to clinical applications?
Moser, E., Stahlberg, F., Ladd, M. E., & Trattnig, S. (2012) · NMR in Biomedicine · doi:10.1002/nbm.1794 · Cited by 187
“UHF is certainly not necessary for this, although FLAIR contrast is obtainable at 7 T (75,76).”
BackgroundIncreased Number of Microinfarcts in Alzheimer Disease at 7-T MR Imaging
van Rooden, S., Goos, J. D. C., van Opstal, A. M., Versluis, M. J., Webb, A. G., Blauw, G. J., van der Flier, W. M., Scheltens, P., Barkhof, F., van Buchem, M. A., et al. (2014) · Radiology · doi:10.1148/radiol.13130743 · Cited by 86
Morphological features of MS lesions on FLAIR* at 7 T and their relation to patient characteristics
Kilsdonk, I. D., Lopez-Soriano, A., Kuijer, J. P. A., de Graaf, W. L., Castelijns, J. A., Polman, C. H., Luijten, P. R., Geurts, J. J. J. G., Barkhof, F., & Wattjes, M. P. (2014) · Journal of Neurology · doi:10.1007/s00415-014-7351-6 · Cited by 55
Self-citation
Metadata
- Authors
- Visser, F., Zwanenburg, J. J. M., Hoogduin, J. M., & Luijten, P. R.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2010-06-22
- Volume
- 64
- Issue
- 1
- Pages
- 194-202
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2013025846
- Cited by
- 114
- References
- 0
- FWCI
- 5.79
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.