The DOI matches its Crossref record; 50 of the 50 references it cites were found in a registry or an index.
Optimized three‐dimensional fast‐spin‐echo MRI
Open accessAbstract
Spin‐echo‐based acquisitions are the workhorse of clinical MRI because they provide a variety of useful image contrasts and are resistant to image artifacts from radio‐frequency or static field inhomogeneity. Three‐dimensional (3D) acquisitions provide datasets that can be retrospectively reformatted for viewing in freely selectable orientations, and are thus advantageous for evaluating the complex anatomy associated with many clinical applications of MRI. Historically, however, 3D spin‐echo‐based acquisitions have not played a significant role in clinical MRI due to unacceptably long acquisition times or image artifacts associated with details of the acquisition method. Recently, optimized forms of 3D fast/turbo spin‐echo imaging have become available from several MR‐equipment manufacturers (for example, CUBE [GE], SPACE [Siemens], and VISTA [Philips]). Through specific design strategies and optimization, including short non–spatially selective radio‐frequency pulses to significantly shorten the echo spacing and variable flip angles for the refocusing radio‐frequency pulses to suppress blurring or considerably lengthen the useable duration of the spin‐echo train, these techniques permit single‐slab 3D imaging of sizeable volumes in clinically acceptable acquisition times. These optimized fast/turbo spin‐echo pulse sequences provide a robust and flexible approach for 3D spin‐echo‐based imaging with a broad range of clinical applications. J. Magn. Reson. Imaging 2014;39:745–767. © 2014 Wiley Periodicals, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
SENSE: Sensitivity encoding for fast MRI
Pruessmann, K. P., Weiger, M., Scheidegger, M. B., & Boesiger, P. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199911)42:5<952::aid-mrm16>3.0.co;2-s · Cited by 6,251
Hahn, E. L. (1950) · Physical Review · doi:10.1103/physrev.80.580 · Cited by 5,085
The Alzheimer’s disease neuroimaging initiative (ADNI): MRI methods
Jack, C. R., Bernstein, M. A., Fox, N. C., Thompson, P., Alexander, G., Harvey, D., Borowski, B., Britson, P. J., L. Whitwell, J., Ward, C., et al. (2008) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21049 · Cited by 4,347
Simultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arrays
Sodickson, D. K., & Manning, W. J. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910380414 · Cited by 2,142
RARE imaging: A fast imaging method for clinical MR
Hennig, J., Nauerth, A., & Friedburg, H. (1986) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910030602 · Cited by 2,081
Multiecho imaging sequences with low refocusing flip angles
Hennig, J. (1988) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(88)90128-x · Cited by 403
Busse, R. F., Hariharan, H., Vu, A., & Brittain, J. H. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20863 · Cited by 335
Optimized Single-Slab Three-dimensional Spin-Echo MR Imaging of the Brain
Mugler, J. P., Bao, S., Mulkern, R. V., Guttmann, C. R. G., Robertson, R. L., Jolesz, F. A., & Brookeman, J. R. (2000) · Radiology · doi:10.1148/radiology.216.3.r00au46891 · Cited by 334
Self-citationQiao, Y., Steinman, D. A., Qin, Q., Etesami, M., Schär, M., Astor, B. C., & Wasserman, B. A. (2011) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.22592 · Cited by 267
Halving MR imaging time by conjugation: demonstration at 3.5 kG.
Feinberg, D. A., Hale, J. D., Watts, J. C., Kaufman, L., & Mark, A. (1986) · Radiology · doi:10.1148/radiology.161.2.3763926 · Cited by 259
Cited by
Multimodal population brain imaging in the UK Biobank prospective epidemiological study
Miller, K. L., Alfaro-Almagro, F., Bangerter, N. K., Thomas, D. L., Yacoub, E., Xu, J., Bartsch, A. J., Jbabdi, S., Sotiropoulos, S. N., Andersson, J. L. R., et al. (2016) · Nature Neuroscience · doi:10.1038/nn.4393 · Cited by 2,020
Image processing and Quality Control for the first 10,000 brain imaging datasets from UK Biobank
Alfaro-Almagro, F., Jenkinson, M., Bangerter, N. K., Andersson, J. L. R., Griffanti, L., Douaud, G., Sotiropoulos, S. N., Jbabdi, S., Hernandez-Fernandez, M., Vallee, E., et al. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2017.10.034 · Cited by 1,557
Kaufmann, T. J., Smits, M., Boxerman, J., Huang, R., Barboriak, D. P., Weller, M., Chung, C., Tsien, C., Brown, P. D., Shankar, L., et al. (2020) · Neuro-Oncology · doi:10.1093/neuonc/noaa030 · Cited by 267
Rapid Musculoskeletal MRI in 2021: Clinical Application of Advanced Accelerated Techniques
Fritz, J., Guggenberger, R., & Grande, F. D. (2021) · American Journal of Roentgenology · doi:10.2214/ajr.20.22902 · Cited by 121
Metadata
- Authors
- Mugler, J. P.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 2014-01-08
- Volume
- 39
- Issue
- 4
- Pages
- 745-767
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W2133016346
- Cited by
- 376
- References
- 50
- FWCI
- 16.36
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Optimized three‐dimensional fast‐spin‐echo MRI. https://app.cochat.ai/papers/10.1002/jmri.24542
- The paper
- Mugler, J. P. (2014). Optimized three‐dimensional fast‐spin‐echo MRI. Journal of Magnetic Resonance Imaging. https://doi.org/10.1002/jmri.24542
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.