The DOI matches its Crossref record.
Transverse relaxometry with stimulated echo compensation
Open accessAbstract
Presented is a fitting model for transverse relaxometry data acquired with the multiple‐refocused spin‐echo sequence. The proposed model, requiring no additional data input or pulse sequence modifications, compensates for imperfections in the transmit field and radiofrequency (RF) profiles. Exploiting oscillatory echo behavior to estimate alternate coherence pathways, the model compensates for prolonged signal decay from stimulated echo pathways yielding precise monoexponential T2 quantification. Verified numerically and experimentally at 4.7 T in phantoms and the human brain, over 95% accuracy is readily attainable in realistic imaging situations without sacrificing multislice capabilities or requiring composite or adiabatic RF pulses. The proposed model allows T2 quantitation in heterogeneous transmit fields and permits thin refocusing widths for efficient multislice imaging. Magn Reson Med, 2010. © 2010 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Jiang, Y., Ma, D., Seiberlich, N., Gulani, V., & Griswold, M. A. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25559 · Cited by 422
MRI‐based myelin water imaging: A technical review
Alonso‐Ortiz, E., Levesque, I. R., & Pike, G. B. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25198 · Cited by 285
Applications of stimulated echo correction to multicomponent T2 analysis
Prasloski, T., Mädler, B., Xiang, Q., MacKay, A., & Jones, C. (2012) · Magnetic Resonance in Medicine · doi:10.1002/mrm.23157 · Cited by 253
Carlier, P. G., Marty, B., Scheidegger, O., Loureiro de Sousa, P., Baudin, P.-Y., Snezhko, E., & Vlodavets, D. (2016) · Journal of Neuromuscular Diseases · doi:10.3233/jnd-160145 · Cited by 186
Effects of formalin fixation and temperature on MR relaxation times in the human brain
Birkl, C., Langkammer, C., Golob‐Schwarzl, N., Leoni, M., Haybaeck, J., Goessler, W., Fazekas, F., & Ropele, S. (2016) · NMR in Biomedicine · doi:10.1002/nbm.3477 · Cited by 111
Metadata
- Authors
- Lebel, R. M., & Wilman, A. H.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2010-06-17
- Volume
- 64
- Issue
- 4
- Pages
- 1005-1014
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2054335197
- Cited by
- 187
- References
- 0
- FWCI
- 4.10
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Transverse relaxometry with stimulated echo compensation. https://app.cochat.ai/papers/10.1002/mrm.22487
- The paper
- Lebel, R. M., & Wilman, A. H. (2010). Transverse relaxometry with stimulated echo compensation. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.22487
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.