CoChat

Imaging near metal with a MAVRIC‐SEMAC hybrid

Koch, K. M., Brau, A. C., Chen, W., Gold, G. E., Hargreaves, B. A., Koff, M., McKinnon, G. C., Potter, H. G., King, K. F. · 2011 · Magnetic Resonance in Medicine
Cited by 230

The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.

Abstract

The recently developed multi‐acquisition with variable resonance image combination (MAVRIC) and slice‐encoding metal artifact correction (SEMAC) techniques can significantly reduce image artifacts commonly encountered near embedded metal hardware. These artifact reductions are enabled by applying alternative spectral and spatial‐encoding schemes to conventional spin‐echo imaging techniques. Here, the MAVRIC and SEMAC concepts are connected and discussed. The development of a hybrid technique that utilizes strengths of both methods is then introduced. The presented technique is shown capable of producing minimal artifact, high‐resolution images near total joint replacements in a clinical setting. Magn Reson Med, 2010. © 2010 Wiley‐Liss, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.22523

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

  • Metal-Induced Artifacts in MRI

    Hargreaves, B. A., Worters, P. W., Pauly, K. B., Pauly, J. M., Koch, K. M., & Gold, G. E. (2011) · American Journal of Roentgenology · doi:10.2214/ajr.11.7364 · Cited by 559

    “A hybrid MAVRIC-SEMAC approach merges features from both original methods into one sequence [30].”
    Self-citation
  • Radiotherapy planning using MRI

    Schmidt, M. A., & Payne, G. S. (2015) · Physics in Medicine and Biology · doi:10.1088/0031-9155/60/22/r323 · Cited by 357

  • Advances in MRI around metal

    Jungmann, P. M., Agten, C. A., Pfirrmann, C. W., & Sutter, R. (2017) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.25708 · Cited by 227

    “Siemens (Erlangen, Germany) calls its dedicated MARS techniques “WARP” (conventional MARS techniques plus VAT) and “advanced WARP” (WARP plus SEMAC) (in alphabetic order).(25,69,70,72) The efficacy of these advanced metal artifact reduction techniques with respect to artifact reduction as compared to conventional sequ…”
    BackgroundMethodInfluential

See all 230

Metadata

Authors
Koch, K. M., Brau, A. C., Chen, W., Gold, G. E., Hargreaves, B. A., Koff, M., McKinnon, G. C., Potter, H. G., & King, K. F.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
2010-10-27
Volume
65
Issue
1
Pages
71-82
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W2119824030
Cited by
230
References
10
FWCI
6.51
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.