The DOI matches its Crossref record.
Fast 3D chemical exchange saturation transfer (CEST) imaging of the human brain
Open accessAbstract
Chemical exchange saturation transfer magnetic resonance imaging can detect low‐concentration compounds with exchangeable protons through saturation transfer to water. This technique is generally slow, as it requires acquisition of saturation images at multiple frequencies. In addition, multislice imaging is complicated by saturation effects differing from slice to slice because of relaxation losses. In this study, a fast three‐dimensional chemical exchange saturation transfer imaging sequence is presented that allows whole‐brain coverage for a frequency‐dependent saturation spectrum (z‐spectrum, 26 frequencies) in less than 10 min. The approach employs a three‐dimensional gradient‐ and spin‐echo readout using a prototype 32‐channel phased‐array coil, combined with two‐dimensional sensitivity encoding accelerations. Results from a homogenous protein‐containing phantom at 3T show that the sequence produced a uniform contrast across all slices. To show translational feasibility, scans were also performed on five healthy human subjects. Results for chemical exchange saturation transfer images at 3.5 ppm downfield of the water resonance, so‐called amide proton transfer images, show that lipid signals are sufficiently suppressed and artifacts caused by B0 inhomogeneity can be removed in postprocessing. The scan time and image quality of these in vivo results show that three‐dimensional chemical exchange saturation trasfer MRI using gradient‐ and spin‐echo acquisition is feasible for whole‐brain chemical exchange saturation transfer studies at 3T in a clinical time frame. Magn Reson Med, 2010. © 2010 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Chemical exchange saturation transfer (CEST): what is in a name and what isn't?
van Zijl, P. C. M., & Yadav, N. N. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22761 · Cited by 1,155
Self-citationAPT‐weighted MRI: Techniques, current neuro applications, and challenging issues
Zhou, J., Heo, H., Knutsson, L., van Zijl, P. C. M., & Jiang, S. (2019) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.26645 · Cited by 345
Self-citationNatural D ‐glucose as a biodegradable MRI contrast agent for detecting cancer
Chan, K. W. Y., McMahon, M. T., Kato, Y., Liu, G., Bulte, J. W. M., Bhujwalla, Z. M., Artemov, D., & van Zijl, P. C. M. (2012) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24520 · Cited by 337
Self-citationNuts and bolts of chemical exchange saturation transfer MRI
Liu, G., Song, X., Chan, K. W. Y., & McMahon, M. T. (2013) · NMR in Biomedicine · doi:10.1002/nbm.2899 · Cited by 318
Nanoparticles for multimodal in vivo imaging in nanomedicine
Leary, J., & Key, J. (2014) · International Journal of Nanomedicine · doi:10.2147/ijn.s53717 · Cited by 300
Metadata
- Authors
- Zhu, H., Jones, C. K., van Zijl, P. C. M., Barker, P. B., & Zhou, J.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2010-08-25
- Volume
- 64
- Issue
- 3
- Pages
- 638-644
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2064347930
- Cited by
- 160
- References
- 0
- FWCI
- 7.23
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Fast 3D chemical exchange saturation transfer (CEST) imaging of the human brain. https://app.cochat.ai/papers/10.1002/mrm.22546
- The paper
- Zhu, H., Jones, C. K., van Zijl, P. C. M., Barker, P. B., & Zhou, J. (2010). Fast 3D chemical exchange saturation transfer (CEST) imaging of the human brain. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.22546
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.