Novel spherical phantoms for Q‐ball imaging under in vivo conditions
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
For the validation of complex diffusion imaging techniques like q‐ball imaging that aim to resolve multiple fiber directions, appropriate phantoms are highly desirable. However, previous q‐ball imaging phantoms had diffusion anisotropies well below those of in vivo white matter. In this work, fiber phantoms of well‐defined geometry are presented. The fibers are wound on a spherical spindle yielding high packing densities and consequently high diffusion anisotropies (fractional anisotropy 0.93 ± 0.02 at b = 500 s/mm 2). Phantoms with 90° and 45° crossing angle were constructed both with two crossing types. In the “stacked” crossing, two fiber strings were wound consecutively to simulate two touching fibers, in the “interleaved” crossing, fibers were wound alternately. The stacked crossing allows the alteration of partial volumes, whereas the interleaved crossing provides constant partial volumes, allowing e.g. the easy alteration of the SNR by varying the slice thickness. Exemplary q‐ball imaging validation measurements using different b‐values and slice thicknesses are presented. Magn Reson Med, 2010. © 2010 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Tuch, D. S. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20279 · Cited by 1,880
Regularized, fast, and robust analytical Q-ball imaging
Descoteaux, M., Angelino, E., Fitzgibbons, S., & Deriche, R. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21277 · Cited by 850
Research works printed but not linked: 23
- 10.1148/radiology.176.2.2367658 · DOI · Paper page
- 10.1002/mrm.20948 · DOI · Paper page
- 10.1016/j.mri.2005.10.015 · DOI
- 10.1016/S1053-8119(03)00154-X · DOI · Paper page
- 10.1002/mrm.10250 · DOI · Paper page
- 10.1016/j.mri.2006.08.001 · DOI
- 10.1016/j.neuroimage.2005.12.052 · DOI
- 10.1016/j.jmr.2007.10.014 · DOI
- 10.1007/s11604-006-0076-4 · DOI
- 10.1098/rstb.2005.1650 · DOI · Paper page
- 10.1002/mrm.21789 · DOI · Paper page
- 10.1016/j.mri.2008.08.011 · DOI
- 10.1002/mrm.20071 · DOI · Paper page
- 10.1002/mrm.22192 · DOI
- AganjI LengletC SapiroG.ODF reconstruction in q‐ball imaging with solid angle consideration. Proceedings of the Sixth IEEE International Symposium on Biomedical Imaging Boston MA2009. · DOI · Paper page
- 10.1016/j.neuroimage.2008.05.002 · DOI · Paper page
- 10.1002/1522-2594(200010)44:4<625::AID-MRM17>3.0.CO;2-O · doi:10.1002/1522-2594(200010)44:4<625::aid-mrm17>3.0.co;2-o
- 10.1002/mrm.21749 · DOI · Paper page
- 10.1016/j.neuroimage.2009.03.077 · DOI
- 10.1002/mrm.1910340618 · DOI · Paper page
- 10.1002/mrm.20931 · DOI · Paper page
- 10.1016/j.neuroimage.2005.04.008 · DOI · Paper page
- 10.1103/RevModPhys.79.1077 · DOI · Paper page
Cited by
Tractography-based connectomes are dominated by false-positive connections
Maier-Hein, K. H., Neher, P., Houde, J.-C., Côté, M.-A., Garyfallidis, E., Zhong, J., Chamberland, M., Yeh, F.-C., Lin, Y.-C., Ji, Q., et al. (2016) · doi:10.1101/084137 · Cited by 1,376
Self-citationAlexander, A. L., Hurley, S. A., Samsonov, A. A., Adluru, N., Hosseinbor, A. P., Mossahebi, P., Tromp, D. P. M., Zakszewski, E., & Field, A. S. (2011) · Brain Connectivity · doi:10.1089/brain.2011.0071 · Cited by 449
Quantitative evaluation of 10 tractography algorithms on a realistic diffusion MR phantom
Fillard, P., Descoteaux, M., Goh, A., Gouttard, S., Jeurissen, B., Malcolm, J., Ramirez-Manzanares, A., Reisert, M., Sakaie, K., Tensaouti, F., et al. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2011.01.032 · Cited by 418
Tractometer: Towards validation of tractography pipelines
Côté, M.-A., Girard, G., Boré, A., Garyfallidis, E., Houde, J.-C., & Descoteaux, M. (2013) · Medical Image Analysis · doi:10.1016/j.media.2013.03.009 · Cited by 228
“, 2011), where synthetic phantom data (Perrin et al., 2005; Fieremans et al., 2008; Pullens et al., 2010; Bach et al., 2011; Moussavi-Biugui et al., 2011), histological data (Leergaard et al.”
BackgroundMapping connectomes with diffusion MRI: deterministic or probabilistic tractography?
Sarwar, T., Ramamohanarao, K., & Zalesky, A. (2019) · Magnetic Resonance in Medicine · doi:10.1002/mrm.27471 · Cited by 182
“The impact of fiber bundle geometry has previously been well studied (61, 62, 64-66, 69, 72, 74).”
BackgroundMethod
Metadata
- Authors
- Moussavi‐Biugui, A., Stieltjes, B., Fritzsche, K., Semmler, W., & Laun, F. B.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2010-08-25
- Volume
- 65
- Issue
- 1
- Pages
- 190-194
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2107806811
- Cited by
- 45
- References
- 2
- FWCI
- 3.13
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.