Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 201

The DOI matches its Crossref record.

Short‐echo, single‐shot, full‐intensity proton magnetic resonance spectroscopy for neurochemical profiling at 4 T: Validation in the cerebellum and brainstem

Open access
Öz, Gülin, Tkáč, Ivan · 2011 · Magnetic Resonance in Medicine

Abstract

A short echo time (TE = 24 ms) semiadiabatic localization by adiabatic selective refocusing (LASER) sequence was designed and optimized for full‐intensity proton magnetic resonance spectroscopy (1 H MRS) at 4 T. The sequence was combined with VAPOR water suppression and three‐dimensional outer volume suppression for improved localization and suppression of unwanted coherences. Artifact‐free, single‐shot spectra were obtained from the human brain with a spectral pattern almost identical to that obtained with an ultra‐short TE (TE = 5 ms) stimulated‐echo acquisition mode (STEAM) sequence as a result of the train of adiabatic refocusing pulses in semi‐LASER that reduce the apparent TE. Approximately 2‐fold higher signal intensity relative to STEAM was demonstrated in phantoms and the human brain. To test the performance of the sequence in clinically relevant brain regions with a volume coil, semi‐LASER spectra were acquired from three cerebellar and brainstem volumes of interest (VOIs) in 23 healthy subjects. Ultra‐short echo STEAM spectra were acquired from the same VOIs to compare neurochemical profiles obtained with semi‐LASER with those obtained with STEAM. Neurochemical profiles of the cerebellum and brainstem acquired by these two techniques were nearly identical, validating the accuracy of the metabolite concentrations obtained with semi‐LASER at the longer TE relative to STEAM. A high correlation between metabolite concentrations obtained by these two proton 1 H MRS techniques indicated the sensitivity to detect intersubject variation in metabolite levels. Magn Reson Med, 2010. © 2010 Wiley‐Liss, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.22708

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Öz, G., & Tkáč, I.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
2010-11-30
Volume
65
Issue
4
Pages
901-910
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W2168936817
Cited by
201
References
0
FWCI
2.65
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.