CoChat

Microscopic and compartment shape anisotropies in gray and white matter revealed by angular bipolar double-PFG MR: d-PFG Reveals Microstructures in Gray Matter

Open access
Shemesh, Noam, Cohen, Yoram · 2011 · Magnetic Resonance in Medicine
Cited by 74

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

Diffusion MR has become one of the most important tools for studying neuronal tissues. Conventional single-pulsed-field-gradient methodologies are capable of faithfully depicting diffusion anisotropy in coherently ordered structures, providing important microstructural information; however, it is extremely difficult to characterize randomly oriented compartments using conventional single-pulsed-field-gradient MR. The angular double-pulsed-field-gradient methodology can potentially overcome the limitations of conventional single-pulsed-field-gradient MR, and offer microstructural information on microscopic anisotropy and compartment shape anisotropy even when anisotropic compartments are completely randomly oriented. Here, we used angular double-pulsed-field-gradient MR at different mixing times to study isolated gray matter and white matter, respectively, and the results are compared with phantoms in which compartments are randomly oriented and coherently organized, respectively. We find that angular bipolar double-pulsed-field-gradient MR offers novel microstructural information, especially in the gray matter, depicting the local microscopic and compartment shape anisotropies present. Furthermore, direct comparison between the angular dependencies arising from white and gray matter at different mixing times reveals signatures for these tissues that are based on compartment shape anisotropy. These findings demonstrate that microstructural information can indeed be obtained from gray matter, and therefore, angular double-pulsed-field-gradient MR is promising for future application in MRI of the central-nervous-system.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.22738

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 74

Metadata

Authors
Shemesh, N., & Cohen, Y.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
2011-02-08
Volume
65
Issue
5
Pages
1216-1227
ISSN
0740-3194 (ISSN-L)
OpenAlex
W2136133131
Cited by
74
References
5
FWCI
4.37
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Microscopic and compartment shape anisotropies in gray and white matter revealed by angular bipolar double-PFG MR: d-PFG Reveals Microstructures in Gray Matter. https://app.cochat.ai/papers/10.1002/mrm.22738
The paper
Shemesh, N., & Cohen, Y. (2011). Microscopic and compartment shape anisotropies in gray and white matter revealed by angular bipolar double-PFG MR: d-PFG Reveals Microstructures in Gray Matter. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.22738

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.