Combining phase images from multi‐channel RF coils using 3D phase offset maps derived from a dual‐echo scan
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
A method is presented for the combination of phase images from multi‐channel RF coils in the absence of a volume reference coil. It is based on the subtraction of 3D phase offset maps from the phase data from each coil. Phase offset maps are weighted combinations of phase measurements at two echo times. Multi‐Channel Phase Combination using measured 3D phase offsets (MCPC‐3D) offers a conceptually and computationally simple solution to the calculation of combined phase images. The dual‐echo data required for the phase maps can be intrinsic to the high‐resorlution gradient‐echo scan to be reconstructed (MCPC‐3D‐I). Alternatively, a separate, fast, low‐resolution dual‐echo scan can be used (MCPC‐3D‐II). Both variants are shown to give near perfect phase matching, yielding images with high SNR throughout and high GM‐WM contrast. MCPC‐3D is compared with other reference‐free phase image crombination methods; high‐pass phase filtering, phase difference imaging, and matching using constant offsets (MCPC‐C). Multi‐Channel Phase Combination using measured 3D phase offsets method does not need an overlap between the signals from individual coils and can be used with parallel imaging, making it ideally suited to multi‐channel coils with a large number of elements, and to high and ultra‐high field systems. Magn Reson Med, 2011. © 2011 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Susceptibility weighted imaging (SWI)
Haacke, E. M., Xu, Y., Cheng, Y. N., & Reichenbach, J. R. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20198 · Cited by 1,582 · cited 1×
“These gradient-echo methods are being applied to assessment of the venous anomalies such as developmental venous anomaly and vascular malformations such as cavernomas (4) and the imaging of iron stores in pathologies such as dementia (5), Huntington’s, Alzheimer’s (6) and Parkinson’s disease.”
MethodImaging iron stores in the brain using magnetic resonance imaging
Haacke, E. M., Cheng, N. Y. C., House, M. J., Liu, Q., Neelavalli, J., Ogg, R. J., Khan, A., Ayaz, M., Kirsch, W., & Obenaus, A. (2005) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2004.10.001 · Cited by 995
Cited by
Quantitative susceptibility mapping (QSM): Decoding MRI data for a tissue magnetic biomarker
Wang, Y., & Liu, T. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25358 · Cited by 878
Quantitative susceptibility mapping: current status and future directions
Haacke, E. M., Liu, S., Buch, S., Zheng, W., Wu, D., & Ye, Y. (2015) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2014.09.004 · Cited by 511
Liu, T., Wisnieff, C., Lou, M., Chen, W., Spincemaille, P., & Wang, Y. (2013) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24272 · Cited by 360
Overview of quantitative susceptibility mapping
Deistung, A., Schweser, F., & Reichenbach, J. R. (2017) · NMR in Biomedicine · doi:10.1002/nbm.3569 · Cited by 338
Yousaf, T., Dervenoulas, G., & Politis, M. (2018) · International Review of Neurobiology · doi:10.1016/bs.irn.2018.08.008 · Cited by 225
Metadata
- Authors
- Robinson, S., Grabner, G., Witoszynskyj, S., & Trattnig, S.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2011-01-19
- Volume
- 65
- Issue
- 6
- Pages
- 1638-1648
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2062580299
- Cited by
- 86
- References
- 2
- FWCI
- 4.60
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Combining phase images from multi‐channel RF coils using 3D phase offset maps derived from a dual‐echo scan. https://app.cochat.ai/papers/10.1002/mrm.22753
- The paper
- Robinson, S., Grabner, G., Witoszynskyj, S., & Trattnig, S. (2011). Combining phase images from multi‐channel RF coils using 3D phase offset maps derived from a dual‐echo scan. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.22753
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.