CoChat

Combining phase images from multi‐channel RF coils using 3D phase offset maps derived from a dual‐echo scan

Open access
Robinson, Simon, Grabner, Günther, Witoszynskyj, Stephan, Trattnig, Siegfried · 2011 · Magnetic Resonance in Medicine
Cited by 86

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

A method is presented for the combination of phase images from multi‐channel RF coils in the absence of a volume reference coil. It is based on the subtraction of 3D phase offset maps from the phase data from each coil. Phase offset maps are weighted combinations of phase measurements at two echo times. Multi‐Channel Phase Combination using measured 3D phase offsets (MCPC‐3D) offers a conceptually and computationally simple solution to the calculation of combined phase images. The dual‐echo data required for the phase maps can be intrinsic to the high‐resorlution gradient‐echo scan to be reconstructed (MCPC‐3D‐I). Alternatively, a separate, fast, low‐resolution dual‐echo scan can be used (MCPC‐3D‐II). Both variants are shown to give near perfect phase matching, yielding images with high SNR throughout and high GM‐WM contrast. MCPC‐3D is compared with other reference‐free phase image crombination methods; high‐pass phase filtering, phase difference imaging, and matching using constant offsets (MCPC‐C). Multi‐Channel Phase Combination using measured 3D phase offsets method does not need an overlap between the signals from individual coils and can be used with parallel imaging, making it ideally suited to multi‐channel coils with a large number of elements, and to high and ultra‐high field systems. Magn Reson Med, 2011. © 2011 Wiley‐Liss, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.22753

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

  • Susceptibility weighted imaging (SWI)

    Haacke, E. M., Xu, Y., Cheng, Y. N., & Reichenbach, J. R. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20198 · Cited by 1,582 · cited 1×

    “These gradient-echo methods are being applied to assessment of the venous anomalies such as developmental venous anomaly and vascular malformations such as cavernomas (4) and the imaging of iron stores in pathologies such as dementia (5), Huntington’s, Alzheimer’s (6) and Parkinson’s disease.”
    Method
  • Imaging iron stores in the brain using magnetic resonance imaging

    Haacke, E. M., Cheng, N. Y. C., House, M. J., Liu, Q., Neelavalli, J., Ogg, R. J., Khan, A., Ayaz, M., Kirsch, W., & Obenaus, A. (2005) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2004.10.001 · Cited by 995

Show all 2 references

Cited by

See all 86

Metadata

Authors
Robinson, S., Grabner, G., Witoszynskyj, S., & Trattnig, S.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
2011-01-19
Volume
65
Issue
6
Pages
1638-1648
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W2062580299
Cited by
86
References
2
FWCI
4.60
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Combining phase images from multi‐channel RF coils using 3D phase offset maps derived from a dual‐echo scan. https://app.cochat.ai/papers/10.1002/mrm.22753
The paper
Robinson, S., Grabner, G., Witoszynskyj, S., & Trattnig, S. (2011). Combining phase images from multi‐channel RF coils using 3D phase offset maps derived from a dual‐echo scan. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.22753

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.