CoChat

Real‐time optical motion correction for diffusion tensor imaging

Open access
Aksoy, Murat, Forman, Christoph, Straka, Matus, Skare, Stefan, Holdsworth, Samantha, Hornegger, Joachim, Bammer, Roland · 2011 · Magnetic Resonance in Medicine
Cited by 116

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Head motion is a fundamental problem in brain MRI. The problem is further compounded in diffusion tensor imaging because of long acquisition times, and the sensitivity of the tensor computation to even small misregistration. To combat motion artifacts in diffusion tensor imaging, a novel real‐time prospective motion correction method was introduced using an in‐bore monovision system. The system consists of a camera mounted on the head coil and a self‐encoded checkerboard marker that is attached to the patient's forehead. Our experiments showed that optical prospective motion correction is more effective at removing motion artifacts compared to image‐based retrospective motion correction. Statistical analysis revealed a significant improvement in similarity between diffusion data acquired at different time points when prospective correction was used compared to retrospective correction (P < 0.001). Magn Reson Med, 2010. © 2011 Wiley‐Liss, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.22787

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 116

Metadata

Authors
Aksoy, M., Forman, C., Straka, M., Skare, S., Holdsworth, S., Hornegger, J., & Bammer, R.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
2011-03-22
Volume
66
Issue
2
Pages
366-378
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W2045453176
Cited by
116
References
1
FWCI
10.11
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Real‐time optical motion correction for diffusion tensor imaging. https://app.cochat.ai/papers/10.1002/mrm.22787
The paper
Aksoy, M., Forman, C., Straka, M., Skare, S., Holdsworth, S., Hornegger, J., & Bammer, R. (2011). Real‐time optical motion correction for diffusion tensor imaging. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.22787

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.