Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 190

The DOI matches its Crossref record.

Combination of complex‐based and magnitude‐based multiecho water‐fat separation for accurate quantification of fat‐fraction

Open access
Yu, Huanzhou, Shimakawa, Ann, Hines, Catherine D. G., McKenzie, Charles A., Hamilton, Gavin, Sirlin, Claude B., Brittain, Jean H., Reeder, Scott B.·2011·Magnetic Resonance in Medicine

Abstract

Multipoint water–fat separation techniques rely on different water–fat phase shifts generated at multiple echo times to decompose water and fat. Therefore, these methods require complex source images and allow unambiguous separation of water and fat signals. However, complex‐based water–fat separation methods are sensitive to phase errors in the source images, which may lead to clinically important errors. An alternative approach to quantify fat is through “magnitude‐based” methods that acquire multiecho magnitude images. Magnitude‐based methods are insensitive to phase errors, but cannot estimate fat‐fraction greater than 50%. In this work, we introduce a water–fat separation approach that combines the strengths of both complex and magnitude reconstruction algorithms. A magnitude‐based reconstruction is applied after complex‐based water–fat separation to removes the effect of phase errors. The results from the two reconstructions are then combined. We demonstrate that using this hybrid method, 0–100% fat‐fraction can be estimated with improved accuracy at low fat‐fractions. Magn Reson Med, 2011. © 2011 Wiley‐Liss, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.22840

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 190

Metadata

Authors
Yu, H., Shimakawa, A., Hines, C. D. G., McKenzie, C. A., Hamilton, G., Sirlin, C. B., Brittain, J. H., & Reeder, S. B.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
2011-02-24
Volume
66
Issue
1
Pages
199-206
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W2114935337
Cited by
190
References
0
FWCI
10.57
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Combination of complex‐based and magnitude‐based multiecho water‐fat separation for accurate quantification of fat‐fraction. https://app.cochat.ai/papers/10.1002/mrm.22840
The paper
Yu, H., Shimakawa, A., Hines, C. D. G., McKenzie, C. A., Hamilton, G., Sirlin, C. B., Brittain, J. H., & Reeder, S. B. (2011). Combination of complex‐based and magnitude‐based multiecho water‐fat separation for accurate quantification of fat‐fraction. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.22840

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.