The DOI matches its Crossref record.
Combination of complex‐based and magnitude‐based multiecho water‐fat separation for accurate quantification of fat‐fraction
Open accessAbstract
Multipoint water–fat separation techniques rely on different water–fat phase shifts generated at multiple echo times to decompose water and fat. Therefore, these methods require complex source images and allow unambiguous separation of water and fat signals. However, complex‐based water–fat separation methods are sensitive to phase errors in the source images, which may lead to clinically important errors. An alternative approach to quantify fat is through “magnitude‐based” methods that acquire multiecho magnitude images. Magnitude‐based methods are insensitive to phase errors, but cannot estimate fat‐fraction greater than 50%. In this work, we introduce a water–fat separation approach that combines the strengths of both complex and magnitude reconstruction algorithms. A magnitude‐based reconstruction is applied after complex‐based water–fat separation to removes the effect of phase errors. The results from the two reconstructions are then combined. We demonstrate that using this hybrid method, 0–100% fat‐fraction can be estimated with improved accuracy at low fat‐fractions. Magn Reson Med, 2011. © 2011 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Quantitative assessment of liver fat with magnetic resonance imaging and spectroscopy
Reeder, S. B., Cruite, I., Hamilton, G., & Sirlin, C. B. (2011) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.22580 · Cited by 822
Self-citationNoninvasive, Quantitative Assessment of Liver Fat by MRI‐PDFF as an Endpoint in NASH Trials
Caussy, C., Reeder, S. B., Sirlin, C. B., & Loomba, R. (2018) · Hepatology · doi:10.1002/hep.29797 · Cited by 563
Self-citationProton density fat‐fraction: A standardized mr‐based biomarker of tissue fat concentration
Reeder, S. B., Hu, H. H., & Sirlin, C. B. (2012) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.23741 · Cited by 501
Self-citationYokoo, T., Serai, S. D., Pirasteh, A., Bashir, M. R., Hamilton, G., Hernando, D., Hu, H. H., Hetterich, H., Kühn, J.-P., Kukuk, G. M., et al. (2018) · Radiology · doi:10.1148/radiol.2017170550 · Cited by 338
Self-citationQuantification of liver fat content with CT and MRI: state of the art
Starekova, J., Hernando, D., Pickhardt, P. J., & Reeder, S. B. (2021) · Radiology · doi:10.1148/radiol.2021204288 · Cited by 320
Metadata
- Authors
- Yu, H., Shimakawa, A., Hines, C. D. G., McKenzie, C. A., Hamilton, G., Sirlin, C. B., Brittain, J. H., & Reeder, S. B.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2011-02-24
- Volume
- 66
- Issue
- 1
- Pages
- 199-206
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2114935337
- Cited by
- 190
- References
- 0
- FWCI
- 10.57
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Combination of complex‐based and magnitude‐based multiecho water‐fat separation for accurate quantification of fat‐fraction. https://app.cochat.ai/papers/10.1002/mrm.22840
- The paper
- Yu, H., Shimakawa, A., Hines, C. D. G., McKenzie, C. A., Hamilton, G., Sirlin, C. B., Brittain, J. H., & Reeder, S. B. (2011). Combination of complex‐based and magnitude‐based multiecho water‐fat separation for accurate quantification of fat‐fraction. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.22840
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.