Spiral phyllotaxis: The natural way to construct a 3D radial trajectory in MRI
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
While radial 3D acquisition has been discussed in cardiac MRI for its excellent results with radial undersampling, the self‐navigating properties of the trajectory need yet to be exploited. Hence, the radial trajectory has to be interleaved such that the first readout of every interleave starts at the top of the sphere, which represents the shell covering all readouts. If this is done sub‐optimally, the image quality might be degraded by eddy current effects, and advanced density compensation is needed. In this work, an innovative 3D radial trajectory based on a natural spiral phyllotaxis pattern is introduced, which features optimized interleaving properties: (1) overall uniform readout distribution is preserved, which facilitates simple density compensation, and (2) if the number of interleaves is a Fibonacci number, the interleaves self‐arrange such that eddy current effects are significantly reduced. These features were theoretically assessed in comparison with two variants of an interleaved Archimedean spiral pattern. Furthermore, the novel pattern was compared with one of the Archimedean spiral patterns, with identical density compensation, in phantom experiments. Navigator‐gated whole‐heart coronary imaging was performed in six healthy volunteers. High reduction of eddy current artifacts and overall improvement in image quality were achieved with the novel trajectory. Magn Reson Med, 2011. © 2011 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sparse MRI: The application of compressed sensing for rapid MR imaging
Lustig, M., Donoho, D., & Pauly, J. M. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21391 · Cited by 6,952 · cited 1×
“Furthermore, the integration of methods exploiting the redundancy of the information contained in the images, such as HYPR (30) or iterative reconstruction methods like compressed sensing (31), to the 3D spiral phyllotaxis pattern represents an attractive possibility (32).”
Method
Cited by
Compressed sensing MRI: a review from signal processing perspective
Ye, J. C. (2019) · BMC Biomedical Engineering · doi:10.1186/s42490-019-0006-z · Cited by 208
Feng, L., Coppo, S., Piccini, D., Yerly, J., Lim, R. P., Masci, P. G., Stuber, M., Sodickson, D. K., & Otazo, R. (2018) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26745 · Cited by 171
“The 3D radial sampling scheme, as shown in Figure 1a&b, is segmented into multiple interleaves based on the spiral phyllotaxis pattern (42), in which each interleave is rotated by the golden-angle about the zaxis with respect to the previous interleave.”
Self-citationFast 3D magnetic resonance fingerprinting for a whole‐brain coverage
Ma, D., Jiang, Y., Chen, Y., McGivney, D., Mehta, B., Gulani, V., & Griswold, M. (2018) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26886 · Cited by 158
Braconnier, P., Milani, B., Loncle, N., Lourenco, J. M., Brito, W., Delacoste, J., Maillard, M., Stuber, M., Burnier, M., & Pruijm, M. (2020) · Journal of Hypertension · doi:10.1097/hjh.0000000000002234 · Cited by 26
Metadata
- Authors
- Piccini, D., Littmann, A., Nielles‐Vallespin, S., & Zenge, M. O.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2011-04-05
- Volume
- 66
- Issue
- 4
- Pages
- 1049-1056
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2145469382
- Cited by
- 179
- References
- 1
- FWCI
- 2.99
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Spiral phyllotaxis: The natural way to construct a 3D radial trajectory in MRI. https://app.cochat.ai/papers/10.1002/mrm.22898
- The paper
- Piccini, D., Littmann, A., Nielles‐Vallespin, S., & Zenge, M. O. (2011). Spiral phyllotaxis: The natural way to construct a 3D radial trajectory in MRI. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.22898
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.