5D whole‐heart sparse MRI
Open accessThe DOI matches its Crossref record; 42 of the 42 references it cites were found in a registry or an index.
Abstract
Purpose: A 5D whole‐heart sparse imaging framework is proposed for simultaneous assessment of myocardial function and high‐resolution cardiac and respiratory motion‐resolved whole‐heart anatomy in a single continuous noncontrast MR scan. Methods: A non–electrocardiograph (ECG)‐triggered 3D golden‐angle radial balanced steady‐state free precession sequence was used for data acquisition. The acquired 3D k‐space data were sorted into a 5D dataset containing separated cardiac and respiratory dimensions using a self‐extracted respiratory motion signal and a recorded ECG signal. Images were then reconstructed using XD‐GRASP, a multidimensional compressed sensing technique exploiting correlations/sparsity along cardiac and respiratory dimensions. 5D whole‐heart imaging was compared with respiratory motion‐corrected 3D and 4D whole‐heart imaging in nine volunteers for evaluation of the myocardium, great vessels, and coronary arteries. It was also compared with breath‐held, ECG‐gated 2D cardiac cine imaging for validation of cardiac function quantification. Results: 5D whole‐heart images received systematic higher quality scores in the myocardium, great vessels and coronary arteries. Quantitative coronary sharpness and length were always better for the 5D images. Good agreement was obtained for quantification of cardiac function compared with 2D cine imaging. Conclusion: 5D whole‐heart sparse imaging represents a robust and promising framework for simplified comprehensive cardiac MRI without the need for breath‐hold and motion correction. Magn Reson Med 79:826–838, 2018. © 2017 International Society for Magnetic Resonance in Medicine.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sparse MRI: The application of compressed sensing for rapid MR imaging
Lustig, M., Donoho, D., & Pauly, J. M. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21391 · Cited by 6,952 · cited 2×
“The sorted 5D whole-heart images were reconstructed using a non-linear conjugate gradient algorithm (46,47).”
SENSE: Sensitivity encoding for fast MRI
Pruessmann, K. P., Weiger, M., Scheidegger, M. B., & Boesiger, P. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199911)42:5<952::aid-mrm16>3.0.co;2-s · Cited by 6,251 · cited 1×
“Although various fast imaging approaches, such as parallel imaging (53-55) and compressed sensing (46,56,57), have been applied to accelerate cardiac MR scans (7,11,58-62), they have had relatively little impact in reducing the complexity of imaging workflow.”
Generalized autocalibrating partially parallel acquisitions (GRAPPA)
Griswold, M. A., Jakob, P. M., Heidemann, R. M., Nittka, M., Jellus, V., Wang, J., Kiefer, B., & Haase, A. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10171 · Cited by 5,303 · cited 1×
“Although various fast imaging approaches, such as parallel imaging (53-55) and compressed sensing (46,56,57), have been applied to accelerate cardiac MR scans (7,11,58-62), they have had relatively little impact in reducing the complexity of imaging workflow.”
Austen, W., Edwards, J., Frye, R., Gensini, G., Gott, V., Griffith, L., McGoon, D., Murphy, M., & Roe, B. (1975) · Circulation · doi:10.1161/01.cir.51.4.5 · Cited by 3,256 · cited 6×
“5D whole-heart images (end-expiratory phase) achieved improved visual delineation of the myocardial wall and different segments of the coronary arteries (white arrows) over 4D whole-heart images, and improved delineation of the LAD over self-navigated 3D whole-heart images.”
InfluentialSimultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arrays
Sodickson, D. K., & Manning, W. J. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910380414 · Cited by 2,142
Self-citationSPIRiT: Iterative self‐consistent parallel imaging reconstruction from arbitrary k‐space
Lustig, M., & Pauly, J. M. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22428 · Cited by 822 · cited 1×
“Although various fast imaging approaches, such as parallel imaging (53-55) and compressed sensing (46,56,57), have been applied to accelerate cardiac MR scans (7,11,58-62), they have had relatively little impact in reducing the complexity of imaging workflow.”
Feng, L., Grimm, R., Block, K. T., Chandarana, H., Kim, S., Xu, J., Axel, L., Sodickson, D. K., & Otazo, R. (2014) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24980 · Cited by 718
Self-citationFeng, L., Axel, L., Chandarana, H., Block, K. T., Sodickson, D. K., & Otazo, R. (2016) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25665 · Cited by 667 · cited 10×
“Images were then reconstructed using XD-GRASP, a multidimensional compressed sensing technique exploiting correlations/sparsity along cardiac and respiratory dimensions.”
InfluentialSelf-citationOtazo, R., Kim, D., Axel, L., & Sodickson, D. K. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22463 · Cited by 571 · cited 1×
“Although various fast imaging approaches, such as parallel imaging (53-55) and compressed sensing (46,56,57), have been applied to accelerate cardiac MR scans (7,11,58-62), they have had relatively little impact in reducing the complexity of imaging workflow.”
Self-citationCompressed sensing in dynamic MRI
Gamper, U., Boesiger, P., & Kozerke, S. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21477 · Cited by 569
Cited by
Küstner, T., Fuin, N., Hammernik, K., Bustin, A., Qi, H., Hajhosseiny, R., Masci, P. G., Neji, R., Rueckert, D., Botnar, R. M., et al. (2020) · Scientific Reports · doi:10.1038/s41598-020-70551-8 · Cited by 233
Self-citation
Metadata
- Authors
- Feng, L., Coppo, S., Piccini, D., Yerly, J., Lim, R. P., Masci, P. G., Stuber, M., Sodickson, D. K., & Otazo, R.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2017-05-11
- Volume
- 79
- Issue
- 2
- Pages
- 826-838
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2612299033
- Cited by
- 171
- References
- 42
- FWCI
- 10.98
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: 5D whole‐heart sparse MRI. https://app.cochat.ai/papers/10.1002/mrm.26745
- The paper
- Feng, L., Coppo, S., Piccini, D., Yerly, J., Lim, R. P., Masci, P. G., Stuber, M., Sodickson, D. K., & Otazo, R. (2018). 5D whole‐heart sparse MRI. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.26745
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.