CoChat

Effect of intercompartmental water exchange on the apparent myelin water fraction in multiexponential T2 measurements of rat spinal cord

Open access
Harkins, Kevin D., Dula, Adrienne N., Does, Mark D. · 2012 · Magnetic Resonance in Medicine
Cited by 91

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

The myelin water fraction has been used as a quantitative measure of the amount of myelin present in tissue. However, recent work has suggested that intercompartmental exchange of water between myelin and nonmyelin compartments may cause the myelin water fraction to underestimate the true myelin content of tissue. In this work, multiexponential T2 experiments were performed in vivo within the rat spinal cord, and a wide variation of the myelin water fraction (10–35%) was measured within four rat spinal cord tracts with similar myelin content. A numerical simulation based upon segmented histology images was used to quantitatively account for T2 variations between tracts. The model predicts that a difference in exchange between the four spinal cord tracts, mediated by a difference in the average axon radius and myelin thickness, is sufficient to account for the variation in myelin water fraction measured in vivo. Magn Reson Med, 2012. © 2011 Wiley Periodicals, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.23053

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 91

Metadata

Authors
Harkins, K. D., Dula, A. N., & Does, M. D.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
2011-06-28
Volume
67
Issue
3
Pages
793-800
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W2088025439
Cited by
91
References
3
FWCI
3.68
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Effect of intercompartmental water exchange on the apparent myelin water fraction in multiexponential T2 measurements of rat spinal cord. https://app.cochat.ai/papers/10.1002/mrm.23053
The paper
Harkins, K. D., Dula, A. N., & Does, M. D. (2012). Effect of intercompartmental water exchange on the apparent myelin water fraction in multiexponential T2 measurements of rat spinal cord. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.23053

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.