The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Fiber orientation-dependent white matter contrast in gradient echo MRI
Open accessAbstract
Recent studies have shown that there is a direct link between the orientation of the nerve fibers in white matter (WM) and the contrast observed in magnitude and phase images acquired using gradient echo MRI. Understanding the origin of this link is of great interest because it could offer access to a new diagnostic tool for investigating tissue microstructure. Since it has been suggested that myelin is the dominant source of this contrast, creating an accurate model for characterizing the effect of the myelin sheath on the evolution of the NMR signal is an essential step toward fully understanding WM contrast. In this study, we show by comparison of the results of simulations and experiments carried out on human subjects at 7T, that the magnitude and phase of signals acquired from WM in vivo can be accurately characterized by ( i ) modeling the myelin sheath as a hollow cylinder composed of material having an anisotropic magnetic susceptibility that is described by a tensor with a radially oriented principal axis, and ( ii ) adopting a two-pool model in which the water in the sheath has a reduced T 2 relaxation time and spin density relative to its surroundings, and also undergoes exchange. The accuracy and intrinsic simplicity of the hollow cylinder model provides a versatile framework for future exploitation of the effect of WM microstructure on gradient echo contrast in clinical MRI.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Zhang, Y., Brady, M., & Smith, S. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.906424 · Cited by 6,982
A global optimisation method for robust affine registration of brain images
Jenkinson, M., & Smith, S. (2001) · Medical Image Analysis · doi:10.1016/s1361-8415(01)00036-6 · Cited by 6,872
Characterization and propagation of uncertainty in diffusion-weighted MR imaging
Behrens, T. E. J., Woolrich, M. W., Jenkinson, M., Johansen‐Berg, H., Nunes, R. G., Clare, S., Matthews, P. M., Brady, J. M., & Smith, S. M. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10609 · Cited by 3,038
In vivo visualization of myelin water in brain by magnetic resonance
Mackay, A., Whittall, K., Adler, J., Li, D., Paty, D., & Graeb, D. (1994) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910310614 · Cited by 914
Schweser, F., Deistung, A., Lehr, B. W., & Reichenbach, J. R. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.10.070 · Cited by 710
High-field MRI of brain cortical substructure based on signal phase
Duyn, J. H., van Gelderen, P., Li, T.-Q., de Zwart, J. A., Koretsky, A. P., & Fukunaga, M. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0610821104 · Cited by 641
Marques, J. P., & Bowtell, R. (2005) · Concepts in Magnetic Resonance Part B: Magnetic Resonance Engineering · doi:10.1002/cmr.b.20034 · Cited by 434
Self-citationMagnetic Resonance of Myelination and Myelin Disorders
van der Knaap, M. S., & Valk, J. (2005) · Springer eBooks · doi:10.1007/3-540-27660-2 · Cited by 394
Water content and myelin water fraction in multiple sclerosis
Laule, C., Vavasour, I. M., Moore, G. R. W., Oger, J., Li, D. K. B., Paty, D. W., & MacKay, A. L. (2004) · Journal of Neurology · doi:10.1007/s00415-004-0306-6 · Cited by 369
Liu, C. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22482 · Cited by 325
Cited by
Quantitative susceptibility mapping (QSM): Decoding MRI data for a tissue magnetic biomarker
Wang, Y., & Liu, T. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25358 · Cited by 878
Myelin and iron concentration in the human brain: a quantitative study of MRI contrast
Stüber, C., Morawski, M., Schäfer, A., Labadie, C., Wähnert, M., Leuze, C., Streicher, M., Barapatre, N., Reimann, K., Geyer, S., et al. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2014.02.026 · Cited by 635
Pros and cons of ultra-high-field MRI/MRS for human application
Ladd, M. E., Bachert, P., Meyerspeer, M., Moser, E., Nagel, A. M., Norris, D. G., Schmitter, S., Speck, O., Straub, S., & Zaiss, M. (2018) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/j.pnmrs.2018.06.001 · Cited by 544
Quantitative susceptibility mapping: current status and future directions
Haacke, E. M., Liu, S., Buch, S., Zheng, W., Wu, D., & Ye, Y. (2015) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2014.09.004 · Cited by 511
Liu, C., Li, W., Tong, K. A., Yeom, K. W., & Kuzminski, S. (2015) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.24768 · Cited by 503
Metadata
- Authors
- Wharton, S., & Bowtell, R.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2012-10-09
- Volume
- 109
- Issue
- 45
- Pages
- 18559-18564
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2021116037
- Cited by
- 316
- References
- 28
- FWCI
- 15.80
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Fiber orientation-dependent white matter contrast in gradient echo MRI. https://app.cochat.ai/papers/10.1073/pnas.1211075109
- The paper
- Wharton, S., & Bowtell, R. (2012). Fiber orientation-dependent white matter contrast in gradient echo MRI. Proceedings of the National Academy of Sciences. https://doi.org/10.1073/pnas.1211075109
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.