Effect of intercompartmental water exchange on the apparent myelin water fraction in multiexponential T2 measurements of rat spinal cord
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
The myelin water fraction has been used as a quantitative measure of the amount of myelin present in tissue. However, recent work has suggested that intercompartmental exchange of water between myelin and nonmyelin compartments may cause the myelin water fraction to underestimate the true myelin content of tissue. In this work, multiexponential T2 experiments were performed in vivo within the rat spinal cord, and a wide variation of the myelin water fraction (10–35%) was measured within four rat spinal cord tracts with similar myelin content. A numerical simulation based upon segmented histology images was used to quantitatively account for T2 variations between tracts. The model predicts that a difference in exchange between the four spinal cord tracts, mediated by a difference in the average axon radius and myelin thickness, is sufficient to account for the variation in myelin water fraction measured in vivo. Magn Reson Med, 2012. © 2011 Wiley Periodicals, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Reaction Rates by Nuclear Magnetic Resonance
McConnell, H. M. (1958) · The Journal of Chemical Physics · doi:10.1063/1.1744152 · Cited by 1,624
An analytical model of restricted diffusion in bovine optic nerve
Stanisz, G. J., Wright, G. A., Henkelman, R. M., & Szafer, A. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910370115 · Cited by 501
Aldehyde fixative solutions alter the water relaxation and diffusion properties of nervous tissue
Shepherd, T. M., Thelwall, P. E., Stanisz, G. J., & Blackband, S. J. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21977 · Cited by 305 · cited 1×
“The natural conclusion is that water exchange plays an even greater role in transverse relaxation in vivo than in the previous study, which consequently indicates that the lower temperature of the ex vivo work ( 18 C) reduced water exchange to a greater extent than it was increased by chemical fixation (25).”
Background
Cited by
Fiber orientation-dependent white matter contrast in gradient echo MRI
Wharton, S., & Bowtell, R. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1211075109 · Cited by 316
MRI‐based myelin water imaging: A technical review
Alonso‐Ortiz, E., Levesque, I. R., & Pike, G. B. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25198 · Cited by 285
Magnetic Resonance of Myelin Water: An in vivo Marker for Myelin
MacKay, A. L., & Laule, C. (2016) · Brain Plasticity · doi:10.3233/bpl-160033 · Cited by 284
Iron, myelin, and the brain: neuroimaging meets neurobiology
Möller, H. E., Bossoni, L., Connor, J. R., Crichton, R. R., Does, M. D., Ward, R. J., Zecca, L., Zucca, F. A., & Ronen, I. (2019) · Trends in Neurosciences · doi:10.1016/j.tins.2019.03.009 · Cited by 207
Self-citationMicro-compartment specific T2⁎ relaxation in the brain
Sati, P., van Gelderen, P., Silva, A. C., Reich, D. S., Merkle, H., de Zwart, J. A., & Duyn, J. H. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.03.005 · Cited by 196
“Reduced or negligible orientation dependence is observed for indicate typical areas in the optic radiations (blue) and GM used for ROI-based fitting (Tab scale (Harkins et al., 2012; Kalantari et al., 2011; Stanisz et al., 1999).”
MethodAn interactive meta-analysis of MRI biomarkers of myelin
Mancini, M., Karakuzu, A., Cohen-Adad, J., Cercignani, M., Nichols, T. E., & Stikov, N. (2020) · eLife · doi:10.7554/elife.61523 · Cited by 168
Quantitative MRI and ultrastructural examination of the cuprizone mouse model of demyelination
Thiessen, J. D., Zhang, Y., Zhang, H., Wang, L., Buist, R., Del Bigio, M. R., Kong, J., Li, X., & Martin, M. (2013) · NMR in Biomedicine · doi:10.1002/nbm.2992 · Cited by 148
So You Want to Image Myelin Using MRI: An Overview and Practical Guide for Myelin Water Imaging
Lee, J., Hyun, J., Lee, J., Choi, E., Shin, H., Min, K., Nam, Y., Kim, H. J., & Oh, S. (2021) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.27059 · Cited by 134
“Additional sources of errors such as intercompartmental water exchange also require attention.(2,42,78) Clinically, the effects of myelin debris(79,80) may complicate the interpretation of MWF, since the short T2 signal is observed not only in intact myelin but also in myelin debris.”
BackgroundPromise and pitfalls of g-ratio estimation with MRI
Campbell, J. S. W., Leppert, I. R., Narayanan, S., Boudreau, M., Duval, T., Cohen-Adad, J., Pike, G. B., & Stikov, N. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2017.08.038 · Cited by 129
“Isolating the short T2 or short T*2 compartment enhances specificity to myelin, but MWF estimates vary nonlinearly with myelin content as the sheath thins and exchange and diffusion properties are modulated (Levesque and Pike, 2009; West et al., 2014; Harkins et al., 2012).”
BackgroundDuyn, J. (2013) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2012.11.013 · Cited by 95
“T2 decay has been observed in WM, and interpreted as arising from distinct contributions from water trapped between myelin sheaths on one hand, and axonal and interstitial (between axons) on the other [89,90].”
BackgroundOn the inherent precision of mcDESPOT
Lankford, C. L., & Does, M. D. (2013) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24241 · Cited by 83
Self-citationFormalin tissue fixation biases myelin – sensitive MRI
Seifert, A. C., Umphlett, M., Hefti, M., Fowkes, M., & Xu, J. (2019) · Magnetic Resonance in Medicine · doi:10.1002/mrm.27821 · Cited by 44
Metadata
- Authors
- Harkins, K. D., Dula, A. N., & Does, M. D.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2011-06-28
- Volume
- 67
- Issue
- 3
- Pages
- 793-800
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2088025439
- Cited by
- 91
- References
- 3
- FWCI
- 3.68
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.