A quantitative pressure and microbubble‐size dependence study of focused ultrasound‐induced blood‐brain barrier opening reversibility in vivo using MRI
Open accessAbstract
Focused ultrasound in conjunction with the systemic administration of microbubbles has been shown to open the blood‐brain barrier (BBB) selectively, noninvasively and reversibly. In this study, we investigate the dependence of the BBB opening's reversibility on the peak‐rarefactional pressure (0.30–0.60 MPa) as well as the microbubble size (diameters of 1–2, 4–5, or 6–8 μm) in mice using contrast‐enhanced T1‐weighted (CE‐T1) MR images (9.4 T). Volumetric measurements of the diffusion of Gd‐DTPA‐BMA into the brain parenchyma were used for the quantification of the BBB‐opened region on the day of sonication and up to 5 days thereafter. The volume of opening was found to increase with both pressure and microbubble diameter. The duration required for closing was found to be proportional to the volume of opening on the day of opening, and ranged from 24 h, for the smaller microbubbles, to 5 days at high peak‐rarefactional pressures. Overall, larger bubbles did not show significant differences. Also, the extent of BBB opening decreased radially towards the focal region until the BBB's integrity was restored. In the cases where histological damage was detected, it was found to be highly correlated with hyperintensity on the precontrast T1 images. Magn Reson Med, 2012. © 2011 Wiley Periodicals, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Astrocyte-endothelial interactions at the blood-brain barrier
Abbott, N. J., Rönnbäck, L., & Hansson, E. (2006) · Nature Reviews Neuroscience · doi:10.1038/nrn1824 · Cited by 5,595
Hynynen, K., McDannold, N., Sheikov, N. A., Jolesz, F. A., & Vykhodtseva, N. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2004.06.046 · Cited by 679
Hynynen, K., McDannold, N., Martin, H., Jolesz, F. A., & Vykhodtseva, N. (2003) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(02)00741-x · Cited by 144
Cited by
Overcoming the Blood–Brain Barrier: The Role of Nanomaterials in Treating Neurological Diseases
Furtado, D., Björnmalm, M., Ayton, S., Bush, A. I., Kempe, K., & Caruso, F. (2018) · Advanced Materials · doi:10.1002/adma.201801362 · Cited by 708
Aryal, M., Arvanitis, C. D., Alexander, P. M., & McDannold, N. (2014) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2014.01.008 · Cited by 443
Ultrasound-responsive systems as components for smart materials
Athanassiadis, A. G., Ma, Z., Moreno-Gomez, N., Melde, K., Choi, E., Goyal, R., & Fischer, P. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00622 · Cited by 293
Gene therapy for the CNS using AAVs: The impact of systemic delivery by AAV9
Saraiva, J., Nobre, R. J., & Pereira de Almeida, L. (2016) · Journal of Controlled Release · doi:10.1016/j.jconrel.2016.09.011 · Cited by 201
Ultrasound targeted CNS gene delivery for Parkinson's disease treatment
Fan, C.-H., Lin, C.-Y., Liu, H.-L., & Yeh, C.-K. (2017) · Journal of Controlled Release · doi:10.1016/j.jconrel.2017.07.004 · Cited by 97
Metadata
- Authors
- Samiotaki, G., Vlachos, F., Tung, Y., & Konofagou, E. E.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2011-08-19
- Volume
- 67
- Issue
- 3
- Pages
- 769-777
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2084355055
- Cited by
- 172
- References
- 3
- FWCI
- 5.47
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.